Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL SYSTEM (for 2WD)
RM37A0E _51 Engine / Hybrid System _086850 HYBRID / BATTERY CONTROL _0420995 MOTOR GENERATOR CONTROL SYSTEM(for 2WD) C

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for 2WD)  P0BE512  Drive Motor "A" Phase U Current Sensor Circuit Short to Battery  P0BE514  Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open  P0BE51F  Drive Motor "A" Phase U Current Sensor Circuit Intermittent  P0BE912  Drive Motor "A" Phase V Current Sensor Circuit Short to Battery  P0BE914  Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open  P0BE91F  Drive Motor "A" Phase V Current Sensor Circuit Intermittent  P0BED12  Drive Motor "A" Phase W Current Sensor Circuit Short to Battery  P0BED14  Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open  P0BED1F  Drive Motor "A" Phase W Current Sensor Circuit Intermittent  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:


Internal inverter malfunction

Inverter with converter assembly internal circuit malfunction


Inverter low-voltage circuit malfunction

The connectors are not connected properly


DESCRIPTION

The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the motor inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0BE512 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery Malfunction in motor inverter current sensor (phase U main sensor)
(Short to +B)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
P0BE514 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open Malfunction in motor inverter current sensor (phase U main sensor)
(Open or short to ground)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
P0BE51F Drive Motor "A" Phase U Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in motor inverter current sensor (phase U main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Does not come on
P0BE912 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery Malfunction in motor inverter current sensor (phase V main sensor)
(Short to +B)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
P0BE914 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open Malfunction in motor inverter current sensor (phase V main sensor)
(Open or short to ground)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
P0BE91F Drive Motor "A" Phase V Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in motor inverter current sensor (phase V main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Does not come on
P0BED12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery Malfunction in motor inverter current sensor (phase W main sensor)
(Short to +B)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
P0BED14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open Malfunction in motor inverter current sensor (phase W main sensor)
(Open or short to ground)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
P0BED1F Drive Motor "A" Phase W Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in motor inverter current sensor (phase W main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Does not come on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 2WD)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the ignition switch to ON and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the ignition switch off and wait for 2 minutes or more.

5.

Turn the ignition switch to ON and turn the GTS on.

6.

With ignition switch ON and wait for 5 seconds or more.

7.

Turn the ignition switch to ON (READY) and wait for 5 seconds or more.

8.

Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.

9.

Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.

10.

Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.

11.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

12.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 2WD)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


PROCEDURE

1.CHECK DTC OUTPUT (MOTOR GENERATOR)
a.

Check for DTCs.

Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
P0BE512, P0BE514, P0BE51F, P0BE912, P0BE914, P0BE91F, P0BED12, P0BED14 and P0BED1F only is output, or DTCs except the ones in the table below are also output. A
Any of the following DTCs including pending DTCs are also output. B


Malfunction Content Relevant DTC
Power source circuit malfunction P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
System malfunction P0A7873 Drive Motor "A" Inverter Actuator Stuck Closed

HINT:

P0BE512, P0BE514, P0BE51F, P0BE912, P0BE914, P0BE91F, P0BED12, P0BED14 and P0BED1F may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





b.

Turn the ignition switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 2WD)>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

REPLACE INVERTER WITH CONVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR