Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)
RM37A0E _51 Engine / Hybrid System _086850 HYBRID / BATTERY CONTROL _0420996 MOTOR GENERATOR CONTROL SYSTEM(for 4WD/AWD) C

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for 4WD/AWD)  P0A0812  DC/DC Converter Status Circuit Short to Battery  P0A0814  DC/DC Converter Status Circuit Short to Ground or Open  


DESCRIPTION

The DC/DC converter varies output voltage based on voltage change signals (VLO signal line) received from the motor generator control ECU.

If the vehicle is being driven with an inoperative DC/DC converter, the voltage of the auxiliary battery will drop, which will prevent the continued operation of the vehicle. Therefore, the motor generator control ECU monitors the operation of the DC/DC converter and alerts the driver if it detects a malfunction.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A0812 DC/DC Converter Status Circuit Short to Battery Short to +B detected in DC/DC converter VLO signal line
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Does not come on Master Warning:
Comes on
P0A0814 DC/DC Converter Status Circuit Short to Ground or Open Open or short to ground detected in DC/DC converter VLO signal line
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Does not come on Master Warning:
Comes on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the ignition switch to ON and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the ignition switch off and wait for 2 minutes or more.

5.

Turn the ignition switch to ON and turn the GTS on.

6.

With ignition switch ON and wait for 10 seconds or more.

7.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




WIRING DIAGRAM

CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

2.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A55 inverter with converter assembly connector.


c.

Remove the IGCT relay from the No. 5 floor relay block and No. 5 floor junction block assembly.


d.

Measure the resistance according to the value(s) in the table below.

A456051C01
3.854,1.698 4.427,2.01 0.573,0.313 5.771,2.885 5.771,1.969 true 0.688,1.688 1,1.885 0.313,0.198 10 false *2 0.604,0.271 0.917,0.469 0.313,0.198 10 false *1 4.198,0.927 4.51,1.125 0.313,0.198 10 false *a 5.635,2.958 6.302,3.167 0.667,0.208 10 false IGCT 4.01,1.771 4.385,1.969 0.375,0.198 10 false A55
*1 No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly *2 IGCT Relay
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
A55-26 (IGCT) - 5 (IGCT relay) Ignition switch off Below 1 Ω



e.

Install the IGCT relay.


f.

Reconnect the A55 inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR