The inverter contains a three-phase bridge circuit, which consists of 6 power transistors (IGBTs) each for the generator (MG1) and rear motor (MGR), and 12 power transistors (IGBTs) for the motor (MG2). The inverter converts high-voltage direct current from the HV battery into three-phase alternating current for the generator (MG1), motor (MG2) and rear motor (MGR); it also converts three-phase alternating current supplied by generator (MG1), motor (MG2) and rear motor (MGR) into direct current for the HV battery. The motor generator control ECU (MG ECU) controls the actuation of the power transistors (IGBTs). The inverter transmits information necessary for control, such as amperage and voltage, to the motor generator control ECU (MG ECU).
The motor generator control ECU (MG ECU) uses an inverter voltage sensor, which is built into the inverter, to detect boosted high voltage (VH) and allow control of the voltage boost.
The inverter voltage sensor outputs voltage that fluctuates between 0 to 5 V according to changes in VH.
The motor generator ECU monitors the inverter voltage sensor and detects the following malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold | Inverter voltage (VH) signal is stuck low:
DTC stored when the VH sensor signal is excessively low. (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold | Inverter voltage (VH) signal is stuck high:
DTC stored when the VH sensor signal is excessively high. (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
| P0D2D1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent | An excessively high or low voltage signal is output from the inverter voltage sensor (VH) when DTC P0C7917, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning:
Does not come on |
| DTC No. | Data List |
|---|---|
| P0D2D16
P0D2D17 P0D2D1F |
VH Voltage |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)>UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
Turn the ignition switch to ON (READY) and wait for 5 seconds or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT