The motor relay and motor fail-safe relay are built into the brake actuator assembly.
When the No. 2 skid control ECU (brake actuator assembly) operates ABS, TRC, VSC, or brake assist, etc., the motor relay turns on and drives the pump motor built into the brake actuator assembly.
If any DTCs related to motor supply power are stored, fail-safe is performed and supply of power to the motor relay is cut by the motor fail-safe relay.
If the voltage supplied to the motor relay (BM terminal) is below the DTC detection threshold due to low voltage from the auxiliary battery or DC/DC converter circuit, these DTCs may be stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Note |
|---|---|---|---|---|
| C052C14 | ABS Pump Motor Control Circuit Short to Ground or Open | When the voltage at terminal +BS is between 9.5 and 17.4 V and the motor is being driven at full power, an abnormal voltage is detected for 0.12 seconds or more. | ·
Wire harness and connector ·
No. 2 skid control ECU (brake actuator assembly) |
Output ECU: No. 2 skid control ECU (brake actuator assembly) |
| C052C16 | ABS Pump Motor Control Circuit Voltage Below Threshold | When the voltage at terminal +BS is between 9.5 and 17.4 V and the motor is stopped, the detected motor voltage is excessively low for 2 seconds or more. | No. 2 skid control ECU (brake actuator assembly) | Output ECU: No. 2 skid control ECU (brake actuator assembly) |
| C052C17 | ABS Pump Motor Control Circuit Voltage Above Threshold | When the voltage at terminal +BS is between 9.5 and 17.4 V and the motor is stopped, the detected motor voltage is excessively high for 2 seconds or more. | No. 2 skid control ECU (brake actuator assembly) | Output ECU: No. 2 skid control ECU (brake actuator assembly) |
| C052C29 | ABS Pump Motor Control Signal Invalid | When the voltage at terminal +BS is between 9.5 and 17.4 V and the motor is being driven, the detected motor voltage is excessively high for 0.12 seconds or more. | No. 2 skid control ECU (brake actuator assembly) | Output ECU: No. 2 skid control ECU (brake actuator assembly) |
| C052C49 | ABS Pump Motor Control Internal Electronic Failure | Either of the following is detected:
·
When the voltage at terminal +BS is between 9.5 and 17.4 V, overcurrent is detected in the motor circuit for 0.05 seconds or more. ·
When the voltage at terminal +BS is between 9.5 and 17.4 V, an abnormal voltage is detected in the motor relay gate for 0.12 seconds or more. |
·
Wire harness and connector ·
No. 2 skid control ECU (brake actuator assembly) |
Output ECU: No. 2 skid control ECU (brake actuator assembly) |
| C052F14 | ABS Pump Motor Supply Voltage Circuit Short to Ground or Open | When voltage at +BS terminal is 9.5 V or more, open in BM terminal continues for 1 second or more. | ·
Wire harness and connector ·
No. 2 skid control ECU (brake actuator assembly) |
Output ECU: No. 2 skid control ECU (brake actuator assembly) |
Inspect the fuses for circuits related to this system before performing the following procedure.
After replacing the No. 2 skid control ECU (brake actuator assembly), perform "Calibration".
| *a | Front view of wire harness connector
(to No. 2 Skid Control ECU (Brake Actuator Assembly)) |
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Disconnect the A57 No. 2 skid control ECU (brake actuator assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A57-46 (BM) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A57-30 (GND2) - Body ground | 1 minute or more after disconnecting the cable from the negative (-) auxiliary battery terminal | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the A57 No. 2 skid control ECU (brake actuator assembly) connector.
Clear the DTCs.
Turn the ignition switch off.
| Proceed to |
|---|
| NEXT |
NEXT
Based on the Freeze Frame Data and interview with the customer, attempt to reproduce the conditions when the malfunction occurred.
Check if the same DTC is output.
| Result | Proceed to |
|---|---|
| DTCs C052C14, C052C16, C052C17, C052C29, C052C49 and C052F14 are not output. | A |
| DTCs C052C14, C052C16, C052C17, C052C29, C052C49 and/or C052F14 are output. | B |
If a speed signal of 20 km/h (12 mph) or more is sent to the No. 2 skid control ECU (brake actuator assembly) with the ignition switch turned to ON and the stop light switch assembly off, the ECU performs self-diagnosis of the motor circuit.
If the normal system code is output (no DTCs are output), slightly jiggle the connectors, wire harness, and fuses of the No. 2 skid control ECU (brake actuator assembly).
If any DTCs are output while jiggling a connector or wire harness of the No. 2 skid control ECU (brake actuator assembly), inspect and repair the connector or wire harness.
If no DTCs were output when reconfirming DTCs, checking for intermittent problems is necessary because it is suspected that the original DTCs were stored due to the poor connection of a connector terminal.
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B