Refer to DTC C123D14.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Note |
|---|---|---|---|---|
| C12C016 | Brake System Control Module Power Supply Voltage Circuit Voltage Below Threshold | When the IG1 terminal voltage is less than 3 V, the IG2 terminal voltage is 9.5 V or more for 4 seconds or more. | ·
Open or short in IG1 circuit ·
Improperly connected connector, deformation or corrosion of terminals ·
No. 2 skid control ECU (brake actuator assembly) |
Output ECU: No. 2 skid control ECU (brake actuator assembly) |
Refer to DTC C137BA2.
Inspect the fuses for circuits related to this system before performing the following procedure.
Before performing troubleshooting, make sure to confirm that the auxiliary battery voltage is normal.
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
After replacing the No. 2 skid control ECU (brake actuator assembly), perform "Calibration".
| *a | Front view of wire harness connector
(to No. 2 Skid Control ECU (Brake Actuator Assembly)) |
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Disconnect the A57 No. 2 skid control ECU (brake actuator assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A57-45 (IG1) - Body ground | Ignition switch ON | 11 to 14 V |
| Result | Proceed to |
|---|---|
| 11 to 14 V. | A |
| Below 11 V. | B |
A
B