1.RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
2.REMOVE PIPING CLAMP (for Suction Hose Sub-assembly Side)
for Low Pressure without Sub-cool Accelerator:
While pressing the end of the suction hose sub-assembly into the end of the suction pipe sub-assembly, use pliers to squeeze together both sides of the piping clamp until it breaks apart.
| *1 | Suction Pipe Sub-assembly | *2 | Suction Hose Sub-assembly |
| *3 | Piping Clamp | - | - |
| *a | Press In | - | - |
If any foreign matter is attached to the connected parts, brush it off or use compressed air to remove it before disconnecting the parts.
Make sure that fragments of the piping clamp do not enter the piping.
Disconnect the suction hose sub-assembly.
Remove any foreign matter from the connecting parts of the suction hose sub-assembly and suction pipe sub-assembly.
Remove the 2 O-rings from the suction hose sub-assembly.
Seal the openings of the disconnected parts with vinyl tape to prevent entry of moisture and foreign matter.
Remove the piping clamp.
| *1 | Suction Pipe Sub-assembly |
| *2 | No. 1 Air Conditioning Accessory Assembly |
Install SST to the piping clamp as shown in the illustration.
| *a | Push in |
Hold the suction pipe sub-assembly and No. 1 air conditioning accessory assembly with each hand and push in SST with both thumbs.
Do not apply excessive force to the suction pipe sub-assembly or No. 1 air conditioning accessory assembly as they may bend.
| *1 | No. 1 Air Conditioning Accessory Assembly |
| *a | Stopper |
| *b | Pull off |
Raise the stopper of SST and remove SST and the piping clamp together from the No. 1 air conditioning accessory assembly.
Remove the piping clamp from SST.
Disconnect the suction pipe sub-assembly.
Remove any foreign matter from the connecting parts of the No. 1 air conditioning accessory assembly and suction pipe sub-assembly.
Remove the 2 O-rings from the suction pipe sub-assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
for Low Pressure with Sub-cool Accelerator:
While pressing the end of the suction hose sub-assembly into the end of the No. 2 air conditioner tube and accessory assembly, use pliers to squeeze together both sides of the piping clamp until it breaks apart.
| *1 | No. 2 Air Conditioner Tube and Accessory Assembly | *2 | Suction Hose Sub-assembly |
| *3 | Piping Clamp | - | - |
| *a | Press In | - | - |
If any foreign matter is attached to the connected parts, brush it off or use compressed air to remove it before disconnecting the parts.
Make sure that fragments of the piping clamp do not enter the piping.
Disconnect the suction hose sub-assembly.
Remove any foreign matter from the connecting parts of the suction hose sub-assembly and No. 2 air conditioner tube and accessory assembly.
Remove the 2 O-rings from the suction hose sub-assembly.
Seal the openings of the disconnected parts with vinyl tape to prevent entry of moisture and foreign matter.
Remove the piping clamp.
| *1 | No. 2 Air Conditioner Tube and Accessory Assembly |
| *2 | No. 1 Air Conditioning Accessory Assembly |
Install SST to the piping clamp as shown in the illustration.
| *a | Push in |
Hold the No. 2 air conditioner tube and accessory assembly and No. 1 air conditioning accessory assembly with each hand and push in SST with both thumbs.
Do not apply excessive force to the No. 2 air conditioner tube and accessory assembly or No. 1 air conditioning accessory assembly as they may bend.
| *1 | No. 1 Air Conditioning Accessory Assembly |
| *a | Stopper |
| *b | Pull off |
Raise the stopper of SST and remove SST and the piping clamp together from the No. 1 air conditioning accessory assembly.
Remove the piping clamp from SST.
Disconnect the No. 2 air conditioner tube and accessory assembly.
Remove any foreign matter from the connecting parts of the No. 1 air conditioning accessory assembly and No. 2 air conditioner tube and accessory assembly.
Remove the 2 O-rings from the No. 2 air conditioner tube and accessory assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
for High Pressure without Sub-cool Accelerator:
| *1 | Cooler Refrigerant Liquid Pipe A |
| *2 | No. 1 Air Conditioning Accessory Assembly |
Install SST to the piping clamp as shown in the illustration.
| *a | Push in |
Hold the cooler refrigerant liquid pipe A and No. 1 air conditioning accessory assembly with each hand and push in SST with both thumbs.
Do not apply excessive force to the cooler refrigerant liquid pipe A or No. 1 air conditioning accessory assembly as they may bend.
| *1 | No. 1 Air Conditioning Accessory Assembly |
| *a | Stopper |
| *b | Pull off |
Raise the stopper of SST and remove SST and the piping clamp together from the No. 1 air conditioning accessory assembly.
Remove the piping clamp from SST.
Disconnect the cooler refrigerant liquid pipe A.
Remove any foreign matter from the connecting parts of the No. 1 air conditioning accessory assembly and cooler refrigerant liquid pipe A.
Remove the 2 O-rings from the cooler refrigerant liquid pipe A.
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
for High Pressure with Sub-cool Accelerator:
| *1 | Air Conditioning Tube Assembly |
| *2 | No. 2 Air Conditioner Tube and Accessory Assembly |
Install SST to the piping clamp as shown in the illustration.
| *a | Push in |
Hold the No. 2 air conditioner tube and accessory assembly and air conditioning tube assembly with each hand and push in SST with both thumbs.
Do not apply excessive force to the No. 2 air conditioner tube and accessory assembly or air conditioning tube assembly as they may bend.
| *1 | Air Conditioning Tube Assembly |
| *a | Stopper |
| *b | Pull off |
Raise the stopper of SST and remove SST and the piping clamp together from the No. 2 air conditioner tube and accessory assembly.
Remove the piping clamp from SST.
Disconnect the No. 2 air conditioner tube and accessory assembly.
Remove any foreign matter from the connecting parts of the air conditioning tube assembly and No. 2 air conditioner tube and accessory assembly.
Remove the 2 O-rings from the No. 2 air conditioner tube and accessory assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
| *1 | No. 2 Air Conditioner Tube and Accessory Assembly |
| *2 | No. 1 Air Conditioning Accessory Assembly |
Install SST to the piping clamp as shown in the illustration.
| *a | Push in |
Hold the No. 2 air conditioner tube and accessory assembly and No. 1 air conditioning accessory assembly with each hand and push in SST with both thumbs.
Do not apply excessive force to the No. 2 air conditioner tube and accessory assembly or No. 1 air conditioning accessory assembly as they may bend.
| *1 | No. 1 Air Conditioning Accessory Assembly |
| *a | Stopper |
| *b | Pull off |
Raise the stopper of SST and remove SST and the piping clamp together from the No. 1 air conditioning accessory assembly.
Remove the piping clamp from SST.
Disconnect the No. 2 air conditioner tube and accessory assembly.
Remove any foreign matter from the connecting parts of the No. 1 air conditioning accessory assembly and No. 2 air conditioner tube and accessory assembly.
Remove the 2 O-rings from the No. 2 air conditioner tube and accessory assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
3.REMOVE PIPING CLAMP (for Air Conditioning Tube Assembly Side)