This DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1423 | Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure | ·
Open or short in air conditioner pressure sensor circuit ·
Refrigerant pressure on high pressure side is extremely low (176 kPaG (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPaG (30.8 kgf/cm2, 439 psi) or more) |
·
Air conditioner pressure sensor ·
Harness or connector ·
Air conditioning amplifier assembly ·
Cooler expansion valve (blocked, stuck) ·
Cooler condenser assembly (blocked, deterioration of cooling capacity due to dirt) ·
Cooler dryer (moisture in the refrigerant cycle cannot be absorbed) ·
Cooling fan system (cooler condenser assembly cannot be cooled down) ·
Air conditioning system (leaks, blocked) ·
Refrigerant volume (excessive, low) |
- |
The air conditioning system uses the CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the air conditioning system after confirming that the communication systems are functioning properly.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC B1423 is output | A |
| DTC B1423 and B14B8 are output | B |
A
B
Install a manifold gauge set.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>ON-VEHICLE INSPECTION
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle Condition | Engine running |
| Doors | Fully closed (windows also fully closed) |
| A/C Switch | On |
| Recirculation/fresh Control Switch | Recirculation |
| Set Temperature | MAX COLD |
| Blower Speed | HI |
| Air Conditioning Air Inlet Temperature | 25 to 35°C (77 to 95°F) |
Compare the values displayed in the Data List and on the manifold gauge.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG (gauge)
Max.: 3294.37 kPaG (gauge) |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
| Result | Proceed to |
|---|---|
| Data List value and manifold gauge set value do not match and Data List value: 176 kPa (1.8 kgf/cm2) or less | A |
| Data List value and manifold gauge set value do not match and Data List value: 3025 kPa (30.9 kgf/cm2) or less | B |
| Data List value matches manifold gauge set value | C |
A
B
C
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG (gauge)
Max.: 3294.37 kPaG (gauge) |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Disconnecting the connector of the air conditioner pressure sensor causes the Data List value to change.
| Result | Proceed to |
|---|---|
| Regulator pressure sensor value changes | A |
| Regulator pressure sensor value does not change | B |
A
B
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the A24 air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-3 (+) - Body ground | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-11 (S5-3) - A24-3 (+) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the A24 air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-2 (PR) - Body ground | Ignition switch ON | 3.0 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-6 (PRE) or A24-2 (PR) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-1 (-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the A24 air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-2 (PR) - Body ground | Ignition switch ON | 3.0 to 5.25 V |
| Result | Proceed to |
|---|---|
| 5.25 V or higher | A |
| 3.0 to 5.25 V | B |
| Below 3.0 V | C |
A
B
C
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-6 (PRE) or A24-2 (PR) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-2 (PR) - A24-3 (+) | Ignition switch off | 180 to 220 kΩ |
After turning the ignition switch off, wait at least 30 seconds before performing the measurement.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-6 (PRE) or A24-2 (PR) - Other terminals and body ground | Always | 10 kΩ or higher |
| H63-11 (S5-3) or A24-3 (+) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-6 (PRE) - A24-2 (PR) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-15 (SG-4) - A24-1 (-) | Always | Below 1 Ω |
| H63-15 (SG-4) or A24-1 (-) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG