Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Manual Air Conditioning System) › from 2020.11
RM37A0E _58 Vehicle Interior _086896 HEATING / AIR CONDITIONING _0453069 AIR CONDITIONING SYSTEM(for Gasoline Model with Manual Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Manual Air Conditioning System)  B1451  Compressor Solenoid Circuit  


DESCRIPTION

The cooler compressor assembly receives refrigerant compression demand signals from the air conditioning amplifier assembly.

Based on this signal, the cooler compressor assembly changes the amount of compressor output.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1451 Compressor Solenoid Circuit Open or short in compressor solenoid circuit
·

Cooler compressor assembly

·

Harness or connector

·

Air conditioning amplifier assembly


-

WIRING DIAGRAM

E432283E01
0.583,2.271 4.01,2.531 3.427,0.26 10 false Cooler Compressor Assembly 0.583,2.115 0.979,2.323 0.396,0.208 10 false C59 1.708,0.677 2.104,0.885 0.396,0.208 10 false SOL+ 1.729,1.469 2.125,1.677 0.396,0.208 10 false SOL- 2.177,0.677 2.573,0.885 0.396,0.208 10 false 2 2.167,1.469 2.563,1.677 0.396,0.208 10 false 1 4.813,0.573 5.208,0.781 0.396,0.208 10 false 18 5.177,0.677 5.573,0.885 0.396,0.208 10 false SOL+ 5.865,0.792 6.26,1 0.396,0.208 10 false IC 4.76,0.781 5.156,0.99 0.396,0.208 10 false H62 4.688,2.104 7,2.417 2.313,0.313 10 false Air Conditioning Amplifier Assembly

PROCEDURE

1.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
a.
E432284C01
1.521,0.281 1.938,0.542 0.417,0.26 2.323,1.823 1.896,1.313 true 1.604,0.333 2.063,0.531 0.458,0.198 10 false C59 3.042,3.406 3.385,3.594 0.344,0.188 10 false GND 2.25,1.865 2.813,2.073 0.563,0.208 10 false SOL+ 0.771,0.396 1.146,0.635 0.375,0.24 12 false *a
*a Front view of wire harness connector
(to Cooler Compressor Assembly)


Disconnect the C59 cooler compressor assembly connector.


b.

Using an oscilloscope, check the waveform.

Item Content
Tester Connection C59-2 (SOL+) - Body ground
Tool Setting 5 V/DIV., 500 μs./DIV.
Condition
·

Engine running

·

Blower switch: LO

·

A/C switch: On



OK:

Waveform is similar to that shown in the illustration.



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (COOLER COMPRESSOR ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
2.CHECK HARNESS AND CONNECTOR (COOLER COMPRESSOR ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the C59 cooler compressor assembly connector.


b.

Disconnect the H62 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C59-2 (SOL+) - H62-18 (SOL+) Always Below 1 Ω
C59-2 (SOL+) or H62-18 (SOL+) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR