HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)  


DESCRIPTION

If the temperature of the air that blows from the left and right front registers differs even though the same temperature is set for both sides, the following factors may be the cause.

Symptom Factor
Temperature of outlet air is cooler on left or right side

(When same temperature set for both sides)


·

Compressor with motor assembly malfunction

·

Refrigerant volume (low)

·

Mechanical locking of damper and damper link

·

Automatic light control sensor malfunction

·

Harness or connector


Temperature of outlet air is warmer on left or right side

(When same temperature set for both sides)


·

Mechanical locking of damper and damper link

·

Blockage in heater radiator unit sub-assembly

·

Harness or connector



WIRING DIAGRAM

E432296E01
0.229,1.021 1.802,1.396 1.573,0.375 10 false Air Conditioning Amplifier Assembly 1.854,3.865 3.219,4.021 1.365,0.156 10 false G5 1.833,4.031 4.052,4.229 2.219,0.198 10 false Automatic Light Control Sensor 4.458,1.76 5.823,1.917 1.365,0.156 10 false H43 4.646,4.01 6.833,4.438 2.188,0.427 10 false Main Body ECU (Multiplex Network Body ECU) 0.76,4.385 2.979,4.583 2.219,0.198 10 false : CAN Communication Line 4.521,1.563 4.979,1.74 0.458,0.177 10 false 23 4.865,1.646 5.323,1.823 0.458,0.177 10 false CLTB 4.51,2.354 4.969,2.531 0.458,0.177 10 false 24 4.865,2.438 5.323,2.615 0.458,0.177 10 false CLTS 4.51,3.01 4.969,3.188 0.458,0.177 10 false 25 4.875,3.094 5.333,3.271 0.458,0.177 10 false CLTE 3.146,1.656 3.604,1.833 0.458,0.177 10 false CLTB 3.615,1.656 4.073,1.833 0.458,0.177 10 false 1 3.146,2.438 3.604,2.615 0.458,0.177 10 false CLTS 3.615,2.438 4.073,2.615 0.458,0.177 10 false 4 3.615,3.104 4.073,3.281 0.458,0.177 10 false 2 3.135,3.094 3.594,3.271 0.458,0.177 10 false CLTE 4.458,2.552 5.823,2.708 1.365,0.156 10 false H43 4.458,3.208 5.823,3.365 1.365,0.156 10 false H43

CAUTION / NOTICE / HINT

NOTICE:

The air conditioning system uses the CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the air conditioning system after confirming that the communication systems are functioning properly.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (for HV Model)>HOW TO PROCEED WITH TROUBLESHOOTING


PROCEDURE

1.CHECK MALFUNCTION STATUS
Result:
Result Proceed to
Malfunction occurs during cooling A
Malfunction occurs during heating B



A

2.CHECK FOR DTC

B

5.BLEED AIR FROM COOLANT (COOLING SYSTEM)
2.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Main Body > Trouble Codes
50001 123

Result:
Result Proceed to
B1244 is not output A
B1244 is output B



A

3.CHECK REFRIGERANT SHORTAGE

B

3.CHECK REFRIGERANT SHORTAGE
a.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
Vehicle Condition Engine running
A/C Switch On
Ambient Temperature*1 0 to 49°C (32 to 120°F)
Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F)
Set Temperature MAX COLD
Recirculation/fresh Control Switch Recirculation
Air Vent Damper Position FACE
Blower Speed HI

HINT:

*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.

*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.



b.

Using the GTS, check the amount of refrigerant.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 121 2186
NOTICE:

If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.


HINT:
·

If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.

·

When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.



Result:
Result Amount of Refrigerant
Refrigerant shortage Insufficient or leakage
Refrigerant correct Correct
Refrigerant incorrect Incorrect


OK:

"Refrigerant correct" is displayed on the GTS.



Result:
Proceed to
OK
NG



OK

4.PERFORM ACTIVE TEST USING GTS (AIR MIX SERVO PULSE)

NG

4.PERFORM ACTIVE TEST USING GTS (AIR MIX SERVO PULSE)
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
OK:

Damper servo motor is operated.



Result:
Proceed to
OK
NG



OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG

GO TO DIAGNOSTIC TROUBLE CODE CHART (FOR SERVO MOTOR OF APPLICABLE ABNORMAL OPERATION)

5.BLEED AIR FROM COOLANT (COOLING SYSTEM)

NEXT

6.CHECK OPERATION (AIR CONDITIONING SYSTEM)
6.CHECK OPERATION (AIR CONDITIONING SYSTEM)
a.

Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.

OK:

The air from the left and right front registers is the same temperature.



Result:
Proceed to
OK
NG



OK

END (FAILURE DUE TO AIR ENTERING COOLANT)

NG

7.PERFORM ACTIVE TEST USING GTS (AIR MIX SERVO PULSE)
7.PERFORM ACTIVE TEST USING GTS (AIR MIX SERVO PULSE)
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
OK:

Damper servo motor is operated.



Result:
Proceed to
OK
NG



OK

NG

GO TO DIAGNOSTIC TROUBLE CODE CHART (FOR SERVO MOTOR OF APPLICABLE ABNORMAL OPERATION)