Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › TOYOTA PARKING ASSIST-SENSOR SYSTEM (w/ Parking Support Brake System (Reverse Only Type)) › from 2020.11
RM37A0E _56 Audio / Visual / Telematics _086880 PARK ASSIST / MONITORING _0454817 TOYOTA PARKING ASSIST-SENSOR SYSTEM(w/ Parking Support Brake System (Reverse Only Type)) J

PARK ASSIST / MONITORING  TOYOTA PARKING ASSIST-SENSOR SYSTEM(w/ Parking Support Brake System (Reverse Only Type))  Buzzer does not Sound  


WIRING DIAGRAM

E329058E44
0.135,1.021 1.469,1.229 1.333,0.208 10 false from IG1-NO. 1 Relay 2.01,1.167 3.104,1.427 1.094,0.26 10 false ECU-IG1 NO. 4 3.323,0.896 3.531,1.094 0.208,0.198 10 false 1 4.75,0.906 4.927,1.094 0.177,0.188 10 false 2 3.115,1.49 3.406,1.677 0.292,0.188 10 false M45 3.115,1.646 4.719,2.302 1.604,0.656 10 false RCTA Buzzer (Blind Spot Monitor Buzzer) 5.438,0.896 5.615,1.083 0.177,0.188 10 false 3 4.375,0.938 4.938,1.146 0.563,0.208 10 false BZN 3.469,0.938 3.781,1.135 0.313,0.198 10 false BZP 5.667,1.021 6.021,1.198 0.354,0.177 10 false BUZ 5.573,1.927 5.896,2.104 0.323,0.177 10 false M2 5.573,2.104 6.813,2.583 1.24,0.479 10 false Blind Spot Monitor Sensor RH (A)

CAUTION / NOTICE / HINT

NOTICE:
·

When checking for DTCs, make sure that the blind spot monitor system is turned on.

·

Inspect the fuses for circuits related to this system before performing the following procedure.



PROCEDURE

1.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Blind Spot Monitor Slave / Data List.


e.

Read the Data List according to the display on the GTS.

Body Electrical > Blind Spot Monitor Slave > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Buzzer Connection Connection status of the buzzer Valid or Invalid Valid: Connection
Invalid: No connection
-
Slave Side RCTA Function Switches the RCTA function on and off OFF or ON OFF: RCTA function off
ON: RCTA function on
-

Body Electrical > Blind Spot Monitor Slave > Data List
Tester Display
Buzzer Connection
Slave Side RCTA Function
50003 314 72,65
Result:
Result Proceed to
"Valid" and "ON" is displayed for all items. A
"Invalid" or "OFF" is displayed. B



A

2.CHECK FOR DTC

B

2.CHECK FOR DTC
a.

According to the display on the GTS, check for DTCs.

Body Electrical > Blind Spot Monitor Slave > Clear DTCs
50002 314

b.

According to the display on the GTS, check for DTCs.

Body Electrical > Blind Spot Monitor Slave > Trouble Codes
50001 314
OK:

No DTCs are output.



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (RCTA BUZZER (BLIND SPOT MONITOR BUZZER) - BLIND SPOT MONITOR SENSOR RH (A) AND POWER SOURCE)

NG

3.CHECK HARNESS AND CONNECTOR (RCTA BUZZER (BLIND SPOT MONITOR BUZZER) - BLIND SPOT MONITOR SENSOR RH (A) AND POWER SOURCE)
a.
E403395C11
1.469,0.583 1.969,0.833 0.5,0.25 1.438,2.177 1.938,2.427 0.5,0.25 1,1.115 1.49,1.375 true 1.896,1.375 2.354,1.083 true 1.688,3.083 2.385,2.615 true 0.708,1.052 1.25,1.25 0.542,0.198 10 false BZP 1.563,0.635 2.104,0.833 0.542,0.198 10 false M45 2.427,1.021 2.969,1.219 0.542,0.198 10 false BZN 2.438,2.542 2.979,2.74 0.542,0.198 10 false BUZ 1.583,2.24 2.125,2.438 0.542,0.198 10 false M2 0.417,0.583 0.979,0.833 0.563,0.25 10 false *a 0.417,2.177 0.833,2.427 0.417,0.25 10 false *b
*a Front view of wire harness connector
(to RCTA Buzzer (Blind Spot Monitor Buzzer))
*b Front view of wire harness connector
(to Blind Spot Monitor Sensor RH (A))


Disconnect the M45 RCTA buzzer (blind spot monitor buzzer) connector.


b.

Disconnect the M2 blind spot monitor sensor RH (A) connector.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
M45-1 (BZP) - Body ground Ignition switch ON 11 to 14 V
M45-2 (BZN) or M2-3 (BUZ) - Body ground Ignition switch ON Below 1 V
M45-2 (BZN) - M45-1 (BZP) Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (RCTA BUZZER (BLIND SPOT MONITOR BUZZER) - BLIND SPOT MONITOR SENSOR RH (A) AND AUXILIARY BATTERY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (RCTA BUZZER (BLIND SPOT MONITOR BUZZER) - BLIND SPOT MONITOR SENSOR RH (A) AND AUXILIARY BATTERY)
a.

Disconnect the M45 RCTA buzzer (blind spot monitor buzzer) connector.


b.

Disconnect the M2 blind spot monitor sensor RH (A) connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M45-2 (BZN) - M2-3 (BUZ) Always Below 1 Ω
M45-2 (BZN) or M2-3 (BUZ) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR