Home
›
ENGINE
›
1TR-FE ENGINE CONTROL SYSTEM
›
KNOCK SENSOR
KNOCK SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT KNOCK SENSOR
Measure the resistance between the terminals.
Standard resistance:
120 to 280 kΩ at 20°C (68°F)
If the result is not as specified, replace the sensor.