DTC P0756 Shift Solenoid "B" Performance (Shift Solenoid Valve S2) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0756 | The gear required by TCM does not match actual gear when driving (2 trip detection logic). |
|
| ACTIVE TEST |
Warm up the engine.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / ECT / Active Test.
According to the display on the tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Control the Shift Position | Operate shift solenoid valve and set each shift position |
| It is possible to check the operation of the shift solenoid valves. [Vehicle Condition] The vehicle speed is 50 km/h (31 mph) or less. |
| TCM gear shift command | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve S2 | OFF | ON | ON | OFF | OFF |
| 1.CHECK DTC OUTPUT (IN ADDITION TO DTC P0756) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / ECT / Trouble Codes.
Read the DTCs using the tester.
| Result | Proceed to |
| Only P0756 is output | A |
| P0756 and other DTCs are output | B |
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SHIFT SOLENOID VALVE SLT) |
![]() |
Remove the test plug on the transmission case center right side and connect SST.
Connect the intelligent tester to the DLC3.
Start the engine and warm it up.
Measure the line pressure with SST.
Turn the intelligent tester on.
Enter the following menus: Powertrain / ECT / Active Test.
According to the display on the tester, perform the Active Test.
Measure the line pressure.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Activate the Solenoid (SLT)* | Operate shift solenoid valve SLT and raise line pressure | ON or OFF
| [Vehicle Condition]
|
|
| ||||
| OK | |
| 3.INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Remove the shift solenoid valve S2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
|
| ||||
| OK | |
| 4.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly.
|
| ||||
| OK | ||
| ||