PARK / NEUTRAL POSITION SWITCH > INSTALLATION |
| 1. INSTALL PARK/NEUTRAL POSITION SWITCH ASSEMBLY |
![]() |
Install the park/neutral position switch to the manual valve shaft.
Temporarily install the bolt.
Install a new lock washer and the nut.
![]() |
Push the control shaft rearward as much as possible.
Return the control shaft lever 2 notches to the N position.
![]() |
Align the neutral basic line with the switch groove, and tighten the bolt.
Using a screwdriver, bend the tabs of the lock washer.
| 2. CONNECT PARK/NEUTRAL POSITION SWITCH CONNECTOR |
| 3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 4. PERFORM INITIALIZATION |
Perform initialization (Click here).
| 5. ADJUST SHIFT LEVER POSITION |
![]() |
Remove the nut and disconnect the control cable.
Remove the clip and disconnect the control cable from the control cable bracket.
![]() |
Push the control shaft rearward as much as possible.
Return the control shaft lever 2 notches to the N position.
While holding the control shaft lever slightly toward the R position side, tighten the nut.
| 6. INSPECT SHIFT LEVER POSITION |
When moving the shift lever from P to R with the ignition switch ON and the brake pedal depressed, make sure that the shift lever moves smoothly and correctly into position.
Start the engine and make sure that the vehicle moves forward after moving the shift lever from N to D, and moves rearward after shifting to R.
If the results are not as specified, inspect the park/neutral position switch and check the shift lever.
| 7. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY |
![]() |
Measure the resistance of the park/neutral switch when the shift lever is moved to each position.
| Tester Connection | Shift Lever Position | Specified Condition |
| 4 (B) - 5 (L) | P or N | Below 1 Ω |
| 4 (B) - 5 (L) | Not on P or N | 10 kΩ or higher |
| 1 (RL) - 2 (RB) | R | Below 1 Ω |
| 1 (RL) - 2 (RB) | Not on R | 10 kΩ or higher |
| 2 (RB) - 7 (DL) | D | Below 1 Ω |
| 2 (RB) - 7 (DL) | Not on D | 10 kΩ or higher |
| 2 (RB) - 3 (2L) | 2 | Below 1 Ω |
| 2 (RB) - 3 (2L) | Not on 2 | 10 kΩ or higher |
| 2 (RB) - 8 (LL) | L | Below 1 Ω |
| 2 (RB) - 8 (LL) | Not on L | 10 kΩ or higher |