COMPRESSOR AND PULLEY (for 1KD-FTV) > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL |
When replacing the compressor with a new one after gradually releasing the refrigerant gas from the service valve, drain the following amount of oil from the new compressor before installation.
| 2. INSTALL COOLER COMPRESSOR ASSEMBLY |
![]() |
Install the compressor with the 4 bolts and tighten the bolts in the order shown in the illustration.
Connect the connector.
| 3. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the vinyl tape attached to the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the compressor.
Install the O-ring on the discharge hose.
| 4. INSTALL SUCTION HOSE SUB-ASSEMBLY |
![]() |
Remove the vinyl tape attached to the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the compressor.
Install the O-ring on the suction hose.
| 5. INSTALL DRIVE BELT |
![]() |
Use the pulley set bolt of the tensioner to rotate the tensioner pulley clockwise, and then install the V belt.
![]() |
Make sure that the indicator mark of the tensioner is within range A, as shown in the illustration.
| 6. INSTALL AIR CLEANER ASSEMBLY |
![]() |
Connect the air cleaner hose.
Install the air cleaner with the 2 bolts.
Tighten the clamp.
Install the clamp and connect the IAT connector.
Connect the ventilation hose.
Slide the clamp to the connection of the hose.
| 7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 8. PERFORM INITIALIZATION |
Perform initialization (Click here).
| 9. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 10. WARM UP ENGINE |
Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging refrigerant.
| 11. CHECK FOR LEAKAGE OF REFRIGERANT |
After recharging the refrigerant gas, prepare the vehicle for a refrigerant gas leakage check by making sure the following conditions are met.
![]() |
Check for refrigerant gas leakage from the refrigerant line.
After the blower motor stops, wait at least 15 minutes.
Using a gas leak detector, check that gas is not leaking from the refrigerant line. If leakage is found, tighten parts or replace damaged parts as necessary to stop the leak.
Check for refrigerant gas leakage from the cooling unit.
Hold the gas leak detector so that the sensor is under the drain hose, as shown in the illustration.
Check that gas is not leaking from the drain hose. If leakage is found, tighten parts or replace damaged parts as necessary to stop the leak.
Check for refrigerant gas leakage from the cooling unit.
Remove the blower motor control from the unit. Insert the gas leak detector's sensor into the unit.
Check that gas is not leaking from the unit. If leakage is found, tighten parts or replace damaged parts as necessary to stop the leak.
Check for refrigerant gas leakage from the pressure switch.
Disconnect the pressure switch connector and wait approximately 20 minutes.
Using a gas leak detector, check that gas is not leaking from the pressure switch. If leakage is found, tighten parts or replace damaged parts as necessary to stop the leak.
Repeat all steps above 2 to 3 times.