CONDENSER (for TR Series Engine) > INSTALLATION |
| 1. INSTALL COOLER CONDENSER ASSEMBLY |
![]() |
Install the cooler condenser.
| 2. INSTALL RADIATOR SUPPORT SUB-ASSEMBLY UPPER |
![]() |
Install the radiator support with the 6 bolts.
| 3. INSTALL HOOD LOCK ASSEMBLY |
![]() |
Install the hood lock with the 3 bolts.
| 4. INSTALL AIR CONDITIONING TUBE AND ACCESSORY ASSEMBLY |
![]() |
Remove the vinyl tape attached to the pipe and connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring on the A/C tube.
Install the A/C tube on the cooler condenser with the bolt.
| 5. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the vinyl tape attached to the pipe and connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.
Install the O-ring on the refrigerant discharge hose.
Install the refrigerant discharge hose on the cooler condenser with the bolt.
| 6. INSTALL FRONT BUMPER REINFORCEMENT SUB-ASSEMBLY |
![]() |
Install the reinforcement with the 4 nuts.
| 7. INSTALL FRONT BUMPER COVER |
w/ Fog light:
Connect the 2 fog light connectors.
![]() |
Put protective tape under the front fender.
Attach the 4 claws to install the cover.
![]() |
Install the 9 clips.
| 8. INSTALL RADIATOR GRILLE |
![]() |
Push the radiator grille in the direction indicated by the arrow in the illustration. Attach the 5 claws to install the radiator grille.
Install the 2 screws and 2 clips.
| 9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 10. PERFORM INITIALIZATION |
Perform initialization (Click here).
| 11. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 12. WARM UP ENGINE |
Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging refrigerant.
| 13. CHECK FOR LEAKAGE OF REFRIGERANT |
After recharging the refrigerant gas, prepare the vehicle for a refrigerant gas leakage check by making sure the following conditions are met.
![]() |
Check for refrigerant gas leakage from the refrigerant line.
After the blower motor stops, wait at least 15 minutes.
Using a gas leak detector, check that gas is not leaking from the refrigerant line. If leakage is found, tighten parts or replace damaged parts as necessary to stop the leak.
Check for refrigerant gas leakage from the cooling unit.
Hold the gas leak detector so that the sensor is under the drain hose, as shown in the illustration.
Check that gas is not leaking from the drain hose. If leakage is found, tighten parts or replace damaged parts as necessary to stop the leak.
Check for refrigerant gas leakage from the cooling unit.
Remove the blower motor control from the unit. Insert the gas leak detector's sensor into the unit.
Check that gas is not leaking from the unit. If leakage is found, tighten parts or replace damaged parts as necessary to stop the leak.
Check for refrigerant gas leakage from the pressure switch.
Disconnect the pressure switch connector and wait approximately 20 minutes.
Using a gas leak detector, check that gas is not leaking from the pressure switch. If leakage is found, tighten parts or replace damaged parts as necessary to stop the leak.
Repeat all steps above 2 to 3 times.