Home › ENGINE ยท 2KD-FTV › CHARGING › GENERATOR (for DENSO Made)

GENERATOR (for DENSO Made) > REMOVAL

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



2. REMOVE AIR CLEANER ASSEMBLY


    A110353
  1. Remove the clamp and disconnect the IAT connector.

  1. Loosen the clamp of the turbocharger.

  1. Slide the clamp and disconnect the ventilation hose.

  1. Remove the 2 bolts and air cleaner.



3. REMOVE FAN AND GENERATOR V BELT
  1. Using the pulley set bolt of the tensioner, rotate the tensioner pulley clockwise to loosen the belt's tension. Then remove the V belt.



4. REMOVE GENERATOR ASSEMBLY


A111821
  1. Remove the nut and generator wire.

  1. Disconnect the generator connector.

  1. Remove the 2 bolts and generator.