Home › ENGINE ยท 1KD-FTV › CHARGING › GENERATOR (for BOSCH Made)

GENERATOR (for BOSCH Made) > REMOVAL

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



2. REMOVE AIR CLEANER ASSEMBLY
  1. for Ventilation Hose Type:
    Disconnect the ventilation hose.

  1. Disconnect the MAF meter connector.

  1. Loosen the hose clamp.

  1. Remove the 2 bolts and air cleaner.



3. REMOVE FAN AND GENERATOR V BELT
  1. Using the pulley set bolt of the tensioner, rotate the tensioner pulley clockwise to loosen the belt's tension. Then remove the V belt.



4. REMOVE GENERATOR ASSEMBLY


A111821
  1. Remove the nut and generator wire.

  1. Disconnect the generator connector.

  1. Remove the 2 bolts and generator.