Home › ENGINE · 1KD-FTV › ENGINE CONTROL SYSTEM › ECD SYSTEM (w/ EGR Cooler)

DTC    P0627    Fuel Pump Control Circuit / Open

for Preparation Click here


DESCRIPTION

Refer to SYSTEM DESCRIPTION (Click here).

DTC No.
DTC Detection Condition
Trouble Area
P0627
Open or short in suction control valve circuit for more than 0.5 seconds (1 trip detection logic)
  1. Open or short in suction control valve circuit
  2. Suction control valve
  3. ECM

HINT:
  1. For more information on the supply pump (suction control valve) and the common rail system, refer to the system description (Click here).
  2. When DTC P0627 is set, check the internal fuel pressure of the common rail by entering the following menus on the intelligent tester: Powertrain / Engine / Data List / Fuel Press.


Reference:

Engine Speed
Fuel Pressure
Idling
Approximately 30 to 40 MPa
3,000 rpm (No engine load)
Approximately 45 to 75 MPa


WIRING DIAGRAM


A154307E03


INSPECTION PROCEDURE

NOTICE:
After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).

HINT:
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.

1.INSPECT SUPPLY PUMP ASSEMBLY (SUCTION CONTROL VALVE)


    A098438E02
  1. Disconnect the S8 suction control valve connector.

  1. Measure the resistance of the suction control valve.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    1.9 to 2.3 Ω



NG
REPLACE SUPPLY PUMP ASSEMBLY (SUCTION CONTROL VALVE) (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (SUCTION CONTROL VALVE - ECM)


    A099839E14
  1. Disconnect the S8 suction control valve connector.

  1. Disconnect the E8 ECM connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    S8-1 - PCV+ (E8-2)
    Below 1 Ω
    S8-2 - PCV- (E8-1)

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    S8-1 or PCV+ (E8-2) - Body ground
    10 kΩ or higher
    S8-2 or PCV- (E8-1) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.INSPECT ECM (PCV VOLTAGE)


    A099840E22
  1. Inspect using the oscilloscope.

  1. During cranking or idling, check the waveform between the specified terminals of the E8 ECM connector.

    Standard:
    Tester Connection
    Specified Condition
    PCV+ (E8-2) - PCV- (E8-1)
    Correct waveform is as shown



NG
REPLACE ECM (Click here)
OK

CHECK FOR INTERMITTENT PROBLEMS (Click here)