DTC 13 Evaporator Temperature Sensor Circuit |
| DTC Code | Detection Item | Trouble Area |
| 13 | Open or short in evaporator temperature sensor circuit |
|

| 1.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (TE VOLTAGE) |
![]() |
Remove the air conditioning amplifier with its connectors still connected.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-1 (TE) - A38-14 (SG-4) | Ignition switch ON Evaporator temperature: 0°C (32°F) | 2.0 to 2.4 V |
| Ignition switch ON Evaporator temperature: 15°C (59°F) | 1.4 to 1.8 V |
| Result | Proceed to |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | A |
| OK (Checking from the DTC) | B |
| NG | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 2.INSPECT NO. 1 COOLER THERMISTOR (A/C THERMISTOR) |
![]() |
Remove the thermistor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| -5°C (23°F) | 5.65 to 6.95 kΩ | |
| 0°C (32°F) | 4.40 to 5.35 kΩ | |
| 5°C (41°F) | 3.40 to 4.15 kΩ | |
| 10°C (50°F) | 2.70 to 3.25 kΩ | |
| 15°C (59°F) | 2.14 to 2.58 kΩ | |
| 20°C (68°F) | 1.71 to 2.05 kΩ | |
| 25°C (77°F) | 1.38 to 1.64 kΩ | |
| 30°C (86°F) | 1.11 to 1.32 kΩ |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the A10 thermistor connector.
Disconnect the A38 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A38-1 (TE) - A10-1 | Always | Below 1 Ω |
| A38-14 (SG-4) - A10-2 | ||
| A38-1 (TE) - Body ground | Always | 10 kΩ or higher |
| A38-14 (SG-4) - Body ground |
|
| ||||
| OK | ||
| ||