Home › ENGINE ยท 5L-E › ENGINE CONTROL SYSTEM › MANIFOLD ABSOLUTE PRESSURE SENSOR

MANIFOLD ABSOLUTE PRESSURE SENSOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. CHECK MANIFOLD ABSOLUTE PRESSURE SENSOR


    A294101E01
  1. Check the power source voltage.
    Text in Illustration 
    *a
    Component without harness connected
    (Manifold Absolute Pressure Sensor)
    V100135
    Disconnect

    1. Disconnect the pressure sensor connector.

    2. Turn the ignition switch ON.

    3. Measure the voltage between terminals M3-3 (VC (+)) and M3-1 (E (-)).

      Standard voltage:
      4.75 to 5.25 V

      If the result is not as specified, inspect the wire harness or ECM (Click here).

    4. Turn the ignition switch off.

    5. Connect the sensor connector.



  1. Check the power supply.

    1. Turn the ignition switch ON.

    2. Disconnect the vacuum hose from the pressure sensor.



    3. A294102E01
    4. Connect a voltmeter to terminals E21-2 (PIM (+)) and E21-9 (E (-)) of the ECM, and measure the output voltage at ambient atmospheric pressure.
      Text in Illustration 
      *a
      Component with harness connected
      (ECM)



    5. A114272
    6. Apply a vacuum to the pressure sensor in 13.3 kPa (100 mmHg, 3.94 in.Hg) increments until the pressure reaches 40.0 kPa (300 mmHg, 11.81 in. Hg).
      Text in Illustration 
      V100135
      Vacuum

    7. Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Applied Vacuum
      Specified Condition
      13.3 kPa (100 mmHg, 3.94 in.Hg)
      0.3 to 0.5 V
      26.7 kPa (200 mmHg, 7.87 in.Hg)
      0.6 to 0.8 V
      40.0 kPa (300 mmHg, 11.81 in.Hg)
      0.95 to 1.15 V

      If the result is not as specified, replace the manifold absolute pressure sensor.



    8. A114273E02
    9. Using SST (turbocharger pressure gauge), apply pressure to the sensor in 19.69 kPa (0.20 kgf/cm2, 2.84 psi) increments until the pressure reaches 98.0 kPa (1.0 kgf/cm2, 14.2 psi).

      SST
      09992-00242  
      Text in Illustration 
      V100135
      Pressure



    10. A294102E01
    11. Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Applied Pressure
      Specified Condition
      19.6 kPa (0.20 kgf/cm2, 2.84 psi)
      0.4 to 0.7 V
      39.2 kPa (0.40 kgf/cm2, 5.69 psi)
      0.9 to 1.2 V
      58.8 kPa (0.60 kgf/cm2, 8.53 psi)
      1.5 to 1.8 V
      78.5 kPa (0.80 kgf/cm2, 11.4 psi)
      2.0 to 2.3 V
      98.0 kPa (1.00 kgf/cm2, 14.2 psi)
      2.5 to 2.8 V

      Text in Illustration 
      *a
      Component with harness connected
      (ECM)
      If the result is not as specified, replace the manifold absolute pressure sensor.

    12. Connect the vacuum hose to the manifold absolute pressure sensor.