Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    21    Solar Sensor Circuit

for Preparation Click here


DESCRIPTION

E132508E01
The cooler thermistor (solar sensor), which is installed on the upper side of the instrument panel, detects sunlight and controls the air conditioning in AUTO mode. The output current from the cooler thermistor (solar sensor) varies according to the amount of sunlight. When the amount of sunlight increases, the output current increases. As the amount of sunlight decreases, the output current decreases. The air conditioning amplifier assembly detects the output current from the cooler thermistor (solar sensor).

DTC Code
Detection Item
Trouble Area
21
An open in cooler thermistor (solar sensor) circuit
(If check is performed in a dark place, DTC 21 may be stored)
  1. Cooler thermistor (solar sensor)
  2. Harness or connector
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E225642E04


INSPECTION PROCEDURE

HINT:
If the check is performed in a dark place, DTC 21 may be stored even though the system is normal.

1.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


    E225456E18
  1. Remove the air conditioning amplifier assembly with its connectors still connected (Click here).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    A37-2 (S5-3) - A37-7 (TS)
    1. Ignition switch ON
    2. Solar sensor subjected to electric light
    3. Vehicle indoors
    0.8 to 4.3 V
    1. Ignition switch ON
    2. Solar sensor covered with a cloth
    3. Vehicle indoors
    Below 0.8 V

    Text in Illustration 
    *a
    Component with harness connected
    (Air Conditioning Amplifier Assembly)

    HINT:
    1. As the inspection light is moved away from the sensor, the voltage decreases.
    2. Use an incandescent light for inspection. Bring it within 30 cm (11.8 in.) of the sensor.

    Result 
    Result
    Proceed to
    OK (When troubleshooting according to problem symptoms table.)
    A
    OK (When troubleshooting according to DTC.)
    B
    NG
    C



B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

C
Go to step 2
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - SOLAR SENSOR)
  1. Disconnect the A37 air conditioning amplifier assembly connector.

  1. Disconnect the A18 cooler thermistor (solar sensor) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A37-2 (S5-3) - A18-1
    Always
    Below 1 Ω
    A37-7 (TS) - A18-2
    A37-2 (S5-3) - Body ground
    Always
    10 kΩ or higher
    A37-7 (TS) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.REPLACE COOLER THERMISTOR (SOLAR SENSOR)
  1. Temporally replace the cooler thermistor (solar sensor) with a new or normally functioning one (Click here).

  1. Clear the DTCs (Click here).

  1. Check the DTCs (Click here).

    OK:
    DTC code 21 is not output.



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK

END (COOLER THERMISTOR [SOLAR SENSOR] IS DEFECTIVE) (Click here)