DTC 21 Solar Sensor Circuit |

| DTC Code | Detection Item | Trouble Area |
| 21 | An open in cooler thermistor (solar sensor) circuit (If check is performed in a dark place, DTC 21 may be stored) |
|

| 1.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY |
![]() |
Remove the air conditioning amplifier assembly with its connectors still connected (Click here).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A37-2 (S5-3) - A37-7 (TS) |
| 0.8 to 4.3 V |
| Below 0.8 V |
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
| Result | Proceed to |
| OK (When troubleshooting according to problem symptoms table.) | A |
| OK (When troubleshooting according to DTC.) | B |
| NG | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - SOLAR SENSOR) |
Disconnect the A37 air conditioning amplifier assembly connector.
Disconnect the A42 cooler thermistor (solar sensor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A37-2 (S5-3) - A42-1 | Always | Below 1 Ω |
| A37-7 (TS) - A42-2 | ||
| A37-2 (S5-3) - Body ground | Always | 10 kΩ or higher |
| A37-7 (TS) - Body ground |
|
| ||||
| OK | |
| 3.REPLACE COOLER THERMISTOR (SOLAR SENSOR) |
Temporally replace the cooler thermistor (solar sensor) with a new or normally functioning one (Click here).
Clear the DTCs (Click here).
Check the DTCs (Click here).
|
| ||||
| OK | ||
| ||