Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › AIRBAG SYSTEM

DTC    B1905/74    Short in Front Passenger Side Pretensioner Squib Circuit

DTC    B1906/74    Open in Front Passenger Side Pretensioner Squib Circuit

DTC    B1907/74    Short to GND in Front Passenger Side Pretensioner Squib Circuit

DTC    B1908/74    Short to B+ in Front Passenger Side Front Pretensioner Squib Circuit

for Preparation Click here


DESCRIPTION

The passenger side front pretensioner squib circuit consists of the center airbag sensor and passenger side front seat outer belt. The circuit instructs the SRS to deploy when deployment conditions are met. These DTCs are recorded when a malfunction is detected in the passenger side front pretensioner squib circuit.

DTC No.
DTC Detection Condition
Trouble Area
B1905/74
When one of following conditions is met:
  1. Center airbag sensor receives line short circuit signal 5 times in passenger side front pretensioner squib circuit during primary check
  2. Passenger side front pretensioner squib malfunction
  3. Center airbag sensor malfunction
  1. Front seat outer belt for passenger side (passenger side front pretensioner squib)
  2. Center airbag sensor assembly
  3. Floor wire
B1906/74
When one of following conditions is met:
  1. Center airbag sensor receives line open circuit signal 5 times in passenger side front pretensioner squib circuit for 2 seconds
  2. Passenger side front pretensioner squib malfunction
  3. Center airbag sensor malfunction
  1. Front seat outer belt for passenger side (passenger side front pretensioner squib)
  2. Center airbag sensor assembly
  3. Floor wire
B1907/74
When one of following conditions is met:
  1. Center airbag sensor receives short circuit to ground signal in passenger side front pretensioner squib circuit for 0.5 seconds
  2. Passenger side front pretensioner squib malfunction
  3. Center airbag sensor malfunction
  1. Front seat outer belt for passenger side (passenger side front pretensioner squib)
  2. Center airbag sensor assembly
  3. Floor wire
B1908/74
When one of following conditions is met:
  1. Center airbag sensor receives short circuit to B+ signal in passenger side front pretensioner squib circuit for 0.5 seconds
  2. Passenger side front pretensioner squib malfunction
  3. Center airbag sensor malfunction
  1. Front seat outer belt for passenger side (passenger side front pretensioner squib)
  2. Center airbag sensor assembly
  3. Floor wire

WIRING DIAGRAM


H101309E46


INSPECTION PROCEDURE

1.CHECK FRONT SEAT OUTER BELT FOR PASSENGER SIDE (PASSENGER SIDE FRONT PRETENSIONER SQUIB)
C306612E01
  1. Turn the ignition switch OFF.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect the connector from the passenger side front seat outer belt.

  1. Connect the white wire side of SST (resistance 2.1 Ω) to the floor wire connector C.

SST
09843-18060  

CAUTION:
Never connect a tester to the passenger side front pretensioner squib for measurement, as this may lead to a serious injury due to airbag deployment.

NOTICE:
  1. Do not forcibly insert SST into the terminals of the connector when connecting.
  2. Insert SST straight into the terminals of the connector.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch OFF.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1905, B1906, B1907, B1908 or 74 is not output.

    HINT:
    DTCs other than DTC B1905, B1906, B1907, B1908 or 74 may be output at this time, but they are not related to this check.



OK
REPLACE FRONT SEAT OUTER BELT FOR PASSENGER SIDE (PASSENGER SIDE FRONT PRETENSIONER SQUIB)
NG


2.CHECK CONNECTOR
  1. Turn the ignition switch OFF.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect SST (resistance 2.1 Ω) from the floor wire.

  1. Check that the floor wire connector (on the passenger side front seat outer belt) is not damaged.

    OK:
    The lock button is not disengaged, or the claw of the lock is not deformed or damaged.



NG
REPAIR OR REPLACE FLOOR WIRE
OK


3.CHECK FLOOR WIRE
C306613E01
  1. Disconnect the connector from the center airbag sensor.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch ON.

  1. for RHD:

    1. Measure the voltage of the wire harness side connector.


Standard voltage:
Type A:
Tester Connection
Specified Condition
F19-1 - Body ground
Below 1 V
F19-2 - Body ground
Below 1 V
Type B:
Tester Connection
Specified Condition
F37-1 - Body ground
Below 1 V
F37-2 - Body ground
Below 1 V

  1. for LHD:

    1. Measure the voltage of the wire harness side connector.


Standard voltage:
Type A:
Tester Connection
Specified Condition
F20-1 - Body ground
Below 1 V
F20-2 - Body ground
Below 1 V
Type B:
Tester Connection
Specified Condition
F38-1 - Body ground
Below 1 V
F38-2 - Body ground
Below 1 V

  1. Turn the ignition switch OFF.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. for RHD:

    1. Measure the resistance of the wire harness side connector.


Standard resistance:
Type A:
Tester Connection
Specified Condition
F19-1 - F19-2
Below 1 Ω
F19-1 - Body ground
1 MΩ or higher
F19-2 - Body ground
1 MΩ or higher
Type B:
Tester Connection
Specified Condition
F37-1 - F37-2
Below 1 Ω
F37-1 - Body ground
1 MΩ or higher
F37-2 - Body ground
1 MΩ or higher

  1. for LHD:

    1. Measure the resistance of the wire harness side connector.


Standard resistance:
Type A:
Tester Connection
Specified Condition
F20-1 - F20-2
Below 1 Ω
F20-1 - Body ground
1 MΩ or higher
F20-2 - Body ground
1 MΩ or higher
Type B:
Tester Connection
Specified Condition
F38-1 - F38-2
Below 1 Ω
F38-1 - Body ground
1 MΩ or higher
F38-2 - Body ground
1 MΩ or higher

  1. Release the activation prevention mechanism built into connector B (Click here).

  1. for RHD:

    1. Measure the resistance of the wire harness side connector.


Standard resistance:
Type A:
Tester Connection
Specified Condition
F19-1 - F19-2
1 MΩ or higher
Type B:
Tester Connection
Specified Condition
F37-1 - F37-2
1 MΩ or higher

  1. for LHD:

    1. Measure the resistance of the wire harness side connector.


Standard resistance:
Type A:
Tester Connection
Specified Condition
F20-1 - F20-2
1 MΩ or higher
Type B:
Tester Connection
Specified Condition
F38-1 - F38-2
1 MΩ or higher



NG
REPAIR OR REPLACE FLOOR WIRE
OK

REPLACE CENTER AIRBAG SENSOR ASSEMBLY