Starter Signal Circuit
Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
While the engine is being cranked, current flows from terminal ST2 of the ignition switch to the ST fuse and also flows to terminal STA of the ECM (STA signal).WIRING DIAGRAM
Refer to DTC P0617 (Click here).INSPECTION PROCEDURE
- HINT:
- This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to the problem symptoms table (Click here).
- NOTICE:
- If the ECM is replaced, the new ECM needs initialization (Click here).
| 1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and turn the intelligent tester ON.
Enter the following menus: Powertrain / Engine / Data List / Starter Signal.
Read the values.
- Standard:
Ignition Switch Position
Starter SIG
ON
OFF
START
ON
|
|
||||
| NG | |
| 2. CHECK WIRE HARNESS (ECM - STARTER RELAY (Marking: ST)) |
Disconnect the E5 ECM connector.

A/T: Remove the starter relay from the engine room relay block.
M/T:Disconnect the 2O junction block connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
A/T Tester Connection
Specified Condition
Relay block starter relay terminal 1 - E5-7 (STA)
Below 1 Ω
Relay block starter relay terminal 1 or E5-7 (STA) - Body ground
10 kΩ or higher
- Standard resistance:
M/T Tester Connection
Specified Condition
2O-19 - E5-7 (STA)
Below 1 Ω
2O-19 - E5-7 (STA) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||