P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2)
Diagnostic trouble codes · Vehicles built from Jun 2011
Also covers:
- P0977 Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2)
DESCRIPTION
Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which is controlled by the TCM. If an open or short circuit occurs in the shift solenoid valves, the TCM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely (Click here).| DTC Code |
DTC Detection Condition |
Trouble Area |
| P0976 |
TCM detects short in solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1 trip detection logic) |
|
| P0977 |
TCM detects open in solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1 trip detection logic) |
|
MONITOR DESCRIPTION
These DTCs indicate an open or short in the shift solenoid valve S2 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem and illuminates the MIL and stores the DTC. When the shift solenoid valve S2 is ON, if resistance is 8 Ω or less, the TCM determines that there is a short in the shift solenoid valve S2 circuit.When the shift solenoid valve S2 is OFF, if resistance is 100 kΩ or more, the TCM determines that there is an open in the shift solenoid valve S2 circuit (Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- The shift solenoid valve S2 turns ON/OFF normally when the shift lever is on D:
TCM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve S2
OFF
ON
ON
OFF
OFF
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2) |
Disconnect the E1 transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
15 - Body ground
20°C (68°F)
11 to 15 Ω
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
Disconnect the T19 TCM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
T19-17 (S2) - Body ground
20°C (68°F)
11 to 15 Ω
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE S2 |
Remove the shift solenoid valve S2.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
20°C (68°F)
11 to 15 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) → Shift solenoid valve S2 connector
- Battery negative (-) → Shift solenoid valve S2 body
Valve moves and makes an operating noise
- Battery positive (+) → Shift solenoid valve S2 connector
|
|
||||
| OK | ||
| ||