P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
Diagnostic trouble codes · Vehicles built from Jun 2011
DESCRIPTION
The amount of current flow to the solenoid is controlled by the duty ratio* of the TCM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.

*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF times (A + B).
Duty Ratio (%) = A/ (A + B) x 100
| DTC Code |
DTC Detection Condition |
Trouble Area |
| P2759 |
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic) |
|
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve SLU circuit is detected, the TCM determines that there is a malfunction. The TCM will illuminate the MIL and store this DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU) |
Disconnect the E1 transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
13 (SLU+) - 5 (SLU-)
20°C (68°F)
5.0 to 5.6 Ω
13 (SLU+) - Body ground
20°C (68°F)
10 kΩ or higher
5 (SLU-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
Disconnect the T19 TCM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
T19-22 (SLU+) - T19-21 (SLU-)
20°C (68°F)
5.0 to 5.6 Ω
T19-22 (SLU+) - Body ground
20°C (68°F)
10 kΩ or higher
T19-21 (SLU-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLU |
Remove the shift solenoid valve SLU.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 2
|
|
||||
| OK | ||
| ||