2014 Hilux · Service Manual ENGINE

Pre-heating Control Circuit

Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014

Versions by build date: Jun 2011 – Oct 2011 Nov 2011 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

When the ignition switch turns ON, the ECM calculates the glow indicator lighting time/heating corresponding to the coolant temperature at that time and turns on the glow indicator light/glow plug relay.
As ceramic is used for glow plug material, the current control is not performed.
A018109E02

WIRING DIAGRAM

A261032E01

INSPECTION PROCEDURE


1. CHECK GLOW INDICATOR LIGHT
  1. Turn the ignition switch ON.

  1. Check that the glow indicator light comes on.

    OK:
    The glow indicator light remains on for 0.5 seconds or more and then goes off.



NG
Go to step 10
OK


2. CHECK GLOW PLUG (INSTALLATION)
  1. Check that the glow plug and glow plug wire are securely installed.

    OK:
    The glow plug and glow plug wire are securely installed.



NG
TIGHTEN GLOW PLUG
OK


3. INSPECT GLOW PLUG

  1. A121949E01
    Measure the resistance of the glow plug.

    Standard resistance:
    0.72 Ω at 20°C (68°F)

    HINT:
    The higher the temperature, the smaller the resistance becomes and vice versa.



NG
REPLACE GLOW PLUG
OK


4. CHECK FOR INDICATOR LIGHTING TIME AND AFTER GLOW TIME


NG
REPLACE ECM
OK


5. READ OUTPUT DTC
  1. Read the DTC (Click here).

    Result:
    Result
    Proceed to
    DTC is not output
    A
    DTC is output
    B



B
GO TO RELEVANT DTC CHART
A


6. INSPECT GLOW RELAY (Marking: GLOW)

  1. A110561E01
    Measure the resistance of the glow relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    (No continuity)
    3 - 5
    Below 1 Ω
    (when battery voltage is applied to terminals 1 and 2)



NG
REPLACE GLOW RELAY
OK


7. CHECK ECM (SREL VOLTAGE)

  1. A062416E50
    Turn the ignition switch to the START position.

  1. Measure the voltage of the ECM connector.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E20-2 (SREL) - E23-14 (E1)
    Cranking
    9 to 14 V



NG
REPLACE ECM
OK


8. CHECK WIRE HARNESS (GLOW RELAY [Marking: GLOW] - ECM AND BODY GROUND)

  1. A121703E01
    Disconnect the E20 ECM connector.

  1. Disconnect the glow relay from the engine room relay block.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    Relay block glow relay terminal 2 - E20-2 (SREL)
    Below 1 Ω
    Relay block glow relay terminal 1 - Body ground
    Below 1 Ω
    E20-2 (SREL) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


9. CHECK WIRE HARNESS (GLOW RELAY [Marking: GLOW] - GLOW PLUG AND BATTERY)

  1. G034668E04
    Disconnect the battery negative (-) cable.

  1. Disconnect the battery positive (+) cable.

  1. Remove the glow relay from the engine room relay block.

  1. Disconnect the glow plug wire.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    Relay block glow relay terminal 3 - Glow plug wire
    Below 1 Ω
    Relay block glow relay terminal 5 - Positive terminal of the battery
    Below 1 Ω

    NOTICE:
    After reconnecting the battery cable, the radio and clock should be adjusted as they were previously.



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

10. CHECK ECM (GIND VOLTAGE)

  1. A062418E08
    Disconnect the E21 ECM connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage of the wire harness side connectors.

    Standard voltage:
    Tester Connection
    Specified Condition
    E21-1 (GIND) - E23-14 (E1)
    9 to 14 V



OK
REPLACE ECM
NG


11. CHECK WIRE HARNESS (ECM - COMBINATION METER)

  1. A121705E04
    Disconnect the C25 combination meter connector.

  1. Disconnect the E21 ECM connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    C25-40 - E21-1 (GIND)
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


12. CHECK FUSE (MET FUSE)

  1. A121706E01
    Remove the MET fuse from the instrument panel junction block.

  1. Measure the resistance of the fuse.

    Standard resistance:
    Tester Connection
    Specified Condition
    MET fuse
    Below 1 Ω



NG
CHECK FOR SHORT IN ALL HARNESSES AND COMPONENTS CONNECTED TO FUSE, AND REPLACE FUSE
OK


13. CHECK WIRE HARNESS (COMBINATION METER - BATTERY)

  1. A121704E07
    Disconnect the C25 combination meter connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    C25-21 - Body ground
    9 to 14 V



OK
REPLACE COMBINATION METER
NG

REPAIR OR REPLACE HARNESS AND CONNECTOR


← Pre-heating Control Circuit (Nov 2011 – Jul 2013)Pre-heating Control Circuit (from Aug 2014) →