ECM Power Source Circuit
Circuit diagnosis · Vehicles built from Jun 2011
DESCRIPTION
When the ignition switch is turned ON, the battery voltage is applied to terminal IGSW of the ECM. The ECM "MREL" output signal causes a current to flow to the MAIN relay coil, closing the contacts of the MAIN relay and supplying power to terminal +B of the ECM.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK ECM (+B VOLTAGE) |
![]() ![]() |
Turn the ignition switch ON.
Measure the voltage of the ECM connectors.
- Standard voltage:
Tester Connection
Specified Condition
E9-1 (+B) - E12-3 (E1)
9 to 14 V
|
|
||||
| NG | |
| 2. CHECK WIRE HARNESS (ECM - BODY GROUND) |
![]() ![]() |
Disconnect the E12 ECM connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
E12-3 (E1) - Body ground
Below 1 Ω
|
|
||||
| OK | |
| 3. CHECK ECM (IGSW VOLTAGE) |
![]() ![]() |
Turn the ignition switch ON.
Measure the voltage of the ECM connectors.
- Standard voltage:
Tester Connection
Specified Condition
E9-9 (IGSW) - E12-3 (E1)
9 to 14 V
|
|
||||
| NG | |
| 4. INSPECT FUSE (IGN) |
![]() ![]() |
Remove the IGN fuse from the instrument panel junction block.
Measure the resistance of the fuse.
- Standard:
- Below 1 Ω
|
|
||||
| OK | |
| 5. INSPECT IGNITION SWITCH ASSEMBLY |
![]() ![]() |
Disconnect the I6 ignition switch connector.
Measure the resistance of the switch.
- Standard resistance:
Tester Connection
Switch Condition
Specified Condition
5 (AM2) - 6 (IG2)
LOCK
10 kΩ or higher
5 (AM2) - 6 (IG2)
ON
Below 1 Ω
|
|
||||
| OK | ||
| ||
| 6. CHECK ECM (MREL VOLTAGE) |
![]() ![]() |
Turn the ignition switch ON.
Measure the voltage of the ECM connectors.
- Standard voltage:
Tester Connection
Specified Condition
E9-8 (MREL) - E12-3 (E1)
9 to 14 V
|
|
||||
| OK | |
| 7. INSPECT FUSE (EFI) |
![]() ![]() |
Remove the EFI fuse from the engine room junction block.
Measure the resistance of the fuse.
- Standard resistance:
- Below 1 Ω
|
|
||||
| OK | |
| 8. CHECK INTEGRATION NO.1 RELAY (MAIN RELAY) |
![]() ![]() |
Disconnect the 1J integration relay connector from the engine room junction block (Click here).
Measure the voltage of the MAIN relay.
- Standard voltage:
Tester Connection
Condition
Specified Condition
1J-4 - Body ground
Ignition switch ON
10 to 14 V
|
|
||||
| OK | |
| 9. CHECK WIRE HARNESS (INTEGRATION RELAY (MAIN RELAY) - ECM, BODY GROUND) |
![]() ![]() |
Disconnect the 1J integration relay connector from the engine room junction block (Click here).
Disconnect the E9 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
1J-2 - E9-8 (MREL)
Below 1 Ω
1J-4 - E9-1 (+B)
Below 1 Ω
1J-3 - Body ground
Below 1 Ω
1J-2 or E9-8 (MREL) - Body ground
10 kΩ or higher
1J-4 or E9-1 (+B) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||