for DPF
Manifold absolute pressure sensor
|
Condition
|
Tester Connection
|
Specified Condition
|
ECM output voltage
|
3 VC (+) - 1 E2 (-)
|
4.75 to 5.25 V
|
Applied vacuum
|
-
|
-
|
13.3 kPa (100 mmHg, 3.94 in.Hg)
|
E27-5 (PIM +) - E27-14 (E2-)
|
0.8 to 1.4 V
|
26.6 kPa (199 mmHg, 7.85 in.Hg)
|
0.5 to 1.0 V
|
40 kPa (300 mmHg, 11.81 in.Hg)
|
0.3 to 0.9 V
|
Applied pressure
|
-
|
-
|
19.6 kPa (0.20 kgf/cm2, 2.84 psi)
|
E27-5 (PIM +) - E27-14 (E2-)
|
1.0 to 1.7 V
|
39.2 kPa (0.40 kgf/cm2, 5.69 psi)
|
1.3 to 1.9 V
|
58.8 kPa (0.60 kgf/cm2, 8.53 psi)
|
1.5 to 2.2 V
|
78.5 kPa (0.80 kgf/cm2, 11.4 psi)
|
1.8 to 2.4 V
|
98.0 kPa (1.00 kgf/cm2, 14.2 psi)
|
2.1 to 2.7 V
|
Turbocharger boost pressure
|
Standard pressure
|
5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi)
|
Turbocharger
|
Axial play of turbine shaft
|
Maximum axial play
|
0.11 mm (0.0043 in.)
|
w/ EGR cooler
Manifold absolute pressure sensor
|
Condition
|
Tester connection
|
Specified Condition
|
ECM output voltage
|
3 (VC (+)) - 1 (E2 (-))
|
4.75 to 5.25 V
|
Applied vacuum
|
-
|
-
|
13.3 kPa (100 mmHg, 3.94 in.Hg)
|
E7-28 (PIM (+)) - E8-28 (E2 (-))
|
0 to 0.3 V
|
26.6 kPa (199 mmHg, 7.85 in.Hg)
|
0.1 to 0.4 V
|
40 kPa (300 mmHg, 11.81 in.Hg)
|
0.2 to 0.6 V
|
Applied pressure
|
-
|
-
|
19. 6 kPa (0.20 kgf/cm2, 2.84 psi)
|
E7-28 (PIM (+)) - E8-28 (E2( -))
|
0.05 to 0.3 V
|
39.2 kPa (0.40 kgf/cm2, 5.69 psi)
|
0.25 to 0.55 V
|
58.8 kPa (0.60 kgf/cm2, 8.53 psi)
|
0.45 to 0.75 V
|
78.5 kPa (0.80 kgf/cm2, 11.4 psi)
|
0.65 to 0.95 V
|
98.0 kPa (1.00 kgf/cm2, 14.2 psi)
|
0.9 to 1.2 V
|
Turbocharger pressure
|
Condition
|
Specified Condition
|
Engine speed (approximately 4600 rpm)
|
10 to 40 kPa (0.10 to 0.41 kgf/cm2, 1.5 to 5.8 psi)
|
Turbocharger
|
Condition
|
Specified Condition
|
Maximum axial play of turbine shaft
|
0.11 mm (0.0043 in.)
|
w/o EGR cooler
Manifold absolute pressure sensor
|
Condition
|
Tester connection
|
Specified Condition
|
ECM output voltage
|
T9-3 (VC (+)) - T9-1 (E2 (-))
|
4.75 to 5.25 V
|
Applied vacuum
|
-
|
-
|
13.3 kPa (100 mmHg, 3.94 in.Hg)
|
E7-28 (PIM) - E8-28 (E2)
|
0.1 to 0.4 V
|
26.6 kPa (199 mmHg, 7.85 in.Hg)
|
0.2 to 0.6 V
|
40 kPa (300 mmHg, 11.81 in.Hg)
|
0.4 to 0.8 V
|
Applied pressure
|
-
|
-
|
19. 6 kPa (0.20 kgf/cm2, 2.84 psi)
|
E7-28 (PIM) - E8-28 (E2)
|
0.1 to 0.4 V
|
39.2 kPa (0.40 kgf/cm2, 5.69 psi)
|
0.4 to 0.7 V
|
58.8 kPa (0.60 kgf/cm2, 8.53 psi)
|
0.7 to 1.0 V
|
78.5 kPa (0.80 kgf/cm2, 11.4 psi)
|
1.0 to 1.3 V
|
98.0 kPa (1.00 kgf/cm2, 14.2 psi)
|
1.3 to 1.6 V
|
Turbocharger pressure
|
Condition
|
Specified Condition
|
Engine speed (approximately 4600 rpm)
|
53 to 83 kPa (0.54 to 0.84 kgf/cm2, 7.6 to 12.0 psi)
|
Turbocharger
|
Condition
|
Specified Condition
|
Maximum axial play of turbine shaft
|
0.08 mm (0.0031 in.)
|
Maximum radial play of turbine shaft
|
0.110 mm (0.0043 in.)
|
Actuator and waste gate valve operation
|
114 kPa (1.16 kgf/cm2, 16.5 psi)
|