2014 Hilux · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built from Aug 2012

Versions by build date: Jun 2011 – Jul 2012 from Aug 2012

for DPF 
Manifold absolute pressure sensor
Condition
Tester Connection
Specified Condition
ECM output voltage
3 VC (+) - 1 E2 (-)
4.75 to 5.25 V
Applied vacuum
-
-
13.3 kPa (100 mmHg, 3.94 in.Hg)
E27-5 (PIM +) - E27-14 (E2-)
0.8 to 1.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.5 to 1.0 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.3 to 0.9 V
Applied pressure
-
-
19.6 kPa (0.20 kgf/cm2, 2.84 psi)
E27-5 (PIM +) - E27-14 (E2-)
1.0 to 1.7 V
39.2 kPa (0.40 kgf/cm2, 5.69 psi)
1.3 to 1.9 V
58.8 kPa (0.60 kgf/cm2, 8.53 psi)
1.5 to 2.2 V
78.5 kPa (0.80 kgf/cm2, 11.4 psi)
1.8 to 2.4 V
98.0 kPa (1.00 kgf/cm2, 14.2 psi)
2.1 to 2.7 V
Turbocharger boost pressure
Standard pressure
5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi)
Turbocharger
Axial play of turbine shaft
Maximum axial play
0.11 mm (0.0043 in.)
w/ EGR cooler 
Vacuum switching valve (for Swirl Control Valve)
Condition
Tester connection
Specified Condition
1 - 2
20 °C (68°F)
33 to 39 Ω
1 - Body ground
2 - Body ground
20 °C (68°F)
10kΩ or higher
Manifold absolute pressure sensor
Condition
Tester connection
Specified Condition
ECM output voltage
3 (VC (+)) - 1 (E2 (-))
4.75 to 5.25 V
Applied vacuum
-
-
13.3 kPa (100 mmHg, 3.94 in.Hg)
E7-28 (PIM (+)) - E8-28 (E2 (-))
0 to 0.3 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.1 to 0.4 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.2 to 0.6 V
Applied pressure
-
-
19. 6 kPa (0.20 kgf/cm2, 2.84 psi)
E7-28 (PIM (+)) - E8-28 (E2( -))
0.05 to 0.3 V
39.2 kPa (0.40 kgf/cm2, 5.69 psi)
0.25 to 0.55 V
58.8 kPa (0.60 kgf/cm2, 8.53 psi)
0.45 to 0.75 V
78.5 kPa (0.80 kgf/cm2, 11.4 psi)
0.65 to 0.95 V
98.0 kPa (1.00 kgf/cm2, 14.2 psi)
0.9 to 1.2 V
Turbocharger pressure
Item
Condition
Specified Condition
(for Waste Gate Type Turbocharger)
Engine speed (4450 to 4750 rpm)
53 to 83 kPa (0.54 to 0.84 kgf/cm2, 7.6 to 12.0 psi)
(for Variable Nozzle Vane Turbocharger)
85 to 115 kPa (0.9 to 1.2 kgf/cm2, 12.3 to 17 psi)
Turbocharger
Item
Condition
Specified Condition
(for Waste Gate Type Turbocharger)
Maximum axial play of turbine shaft
0.08 mm (0.0031 in.)
Maximum radial play of turbine shaft
0.110 mm (0.0043 in.)
Actuator and waste gate valve operation
108 kPa (1.10 kgf/cm2, 16 psi)
(for Variable Nozzle Vane Turbocharger)
Maximum axial play of turbine shaft
0.110 mm (0.00433 in.)
w/o EGR cooler 
Vacuum switching valve (for Swirl Control Valve)
(w/ Intercooler)
Condition
Tester connection
Specified Condition
1 - 2
20 °C (68°F)
33 to 39 Ω
1 - Body ground
2 - Body ground
20 °C (68°F)
10kΩ or higher
Manifold absolute pressure sensor
Condition
Tester connection
Specified Condition
(w/ Intercooler)
ECM output voltage
T9-3 (VC (+)) - T9-1 (E2 (-))
4.75 to 5.25 V
(w/o Intercooler)
4.5 to 5.5 V
-
Applied vacuum
-
-
(w/ Intercooler)
13.3 kPa (100 mmHg, 3.94 in.Hg)
E7-28 (PIM) - E8-28 (E2)
0.0 to 0.3 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.1 to 0.4 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.3 to 0.6 V
(w/o Intercooler)
13.3 kPa (100 mmHg, 3.94 in.Hg)
E7-28 (PIM) - E8-28 (E2)
0.1 to 0.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.2 to 0.6 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.4 to 0.8 V
-
Applied pressure
-
-
(w/ Intercooler)
19. 6 kPa (0.20 kgf/cm2, 2.84 psi)
E7-28 (PIM) - E8-28 (E2)
0.05 to 0.3 V
39.2 kPa (0.40 kgf/cm2, 5.69 psi)
0.25 to 0.55 V
58.8 kPa (0.60 kgf/cm2, 8.53 psi)
0.45 to 0.75 V
78.5 kPa (0.80 kgf/cm2, 11.4 psi)
0.65 to 0.95 V
98.0 kPa (1.00 kgf/cm2, 14.2 psi)
0.9 to 1.2 V
(w/o Intercooler)
19. 6 kPa (0.20 kgf/cm2, 2.84 psi)
E7-28 (PIM) - E8-28 (E2)
0.1 to 0.4 V
39.2 kPa (0.40 kgf/cm2, 5.69 psi)
0.4 to 0.7 V
58.8 kPa (0.60 kgf/cm2, 8.53 psi)
0.7 to 1.0 V
78.5 kPa (0.80 kgf/cm2, 11.4 psi)
1.0 to 1.3 V
98.0 kPa (1.00 kgf/cm2, 14.2 psi)
1.3 to 1.6 V
Turbocharger pressure
Item
Condition
Specified Condition
(w/ Intercooler)
Engine speed (4450 to 4750 rpm)
85 to 115 kPa (0.9 to 1.2 kgf/cm2, 12.3 to 17 psi)
(w/o Intercooler)
53 to 83 kPa (0.54 to 0.84 kgf/cm2, 7.6 to 12.0 psi)
Turbocharger
Item
Condition
Specified Condition
(w/ Intercooler)
Maximum axial play of turbine shaft
0.11 mm (0.00433 in.)
(w/o Intercooler)
Maximum axial play of turbine shaft
0.08 mm (0.0031 in.)
Maximum radial play of turbine shaft
0.110 mm (0.0043 in.)
Actuator and waste gate valve operation
108 kPa (1.10 kgf/cm2, 16 psi)
← SERVICE DATA (Jun 2011 – Jul 2012)TORQUE SPECIFICATIONS (Jun 2011 – Jul 2012) →