2014 Hilux · Service Manual HEATER & AIR CONDITIONING SYSTEM

12 Ambient Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built from Aug 2013

Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 from Aug 2013

DESCRIPTION

The thermistor assembly connected to the accessory meter detects fluctuations in the ambient temperature. This information is used for controlling the interior temperature. The accessory meter assembly detects the resistance of the thermistor assembly and sends this information to the air conditioning amplifier assembly.
DTC Code
DTC Detection Condition
Trouble Area
12
An open or short in ambient temperature sensor circuit
  1. Thermistor assembly
  2. Accessory meter assembly
  3. Air conditioning amplifier assembly
  4. Harness or connector

WIRING DIAGRAM

E227734E03

INSPECTION PROCEDURE

NOTICE:
Check that the accessory meter assembly illuminates normally before performing the following inspection procedure.


1. CHECK ACCESSORY METER ASSEMBLY
  1. Check the difference between the ambient temperature value displayed on the accessory meter assembly and the actual ambient temperature.

    OK:
    The ambient temperature displayed on the accessory meter assembly and the actual ambient temperature are almost the same.

    HINT:
    The temperature displayed on the accessory meter assembly and the actual temperature detected by the thermistor assembly may differ when the ambient temperature changes significantly (for example, when the vehicle is entering/exiting tunnels, or the vehicle speed or wind direction changes).



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (ACCESSORY METER - AIR CONDITIONING AMPLIFIER)
  1. Disconnect the A27 accessory meter assembly connector.

  1. Disconnect the A44 air conditioning amplifier assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A27-9 (DATA) - A44-18 (TAMO)
    Always
    Below 1 Ω
    A27-9 (DATA) - Body ground
    Always
    10 kΩ or higher

    Result 
    Result
    Proceed to
    OK (When troubleshooting according to problem symptoms table.)
    A
    OK (When troubleshooting according to DTC.)
    B
    NG
    C



B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

C
REPAIR OR REPLACE HARNESS OR CONNECTOR
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

3. INSPECT THERMISTOR ASSEMBLY

  1. E170945E02
    Remove the thermistor assembly (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    Text in Illustration 
    *a
    Resistance (kΩ)
    *b
    Temperature

    NOTICE:
    1. Even slightly touching the thermistor assembly may change the resistance value. Be sure to hold the connector of the thermistor assembly.
    2. When measuring the resistance, the thermistor assembly temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (Refer to the graph).



NG
REPLACE THERMISTOR ASSEMBLY (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (THERMISTOR - ACCESSORY METER)
  1. Disconnect the A39*1 or A26*2 thermistor assembly connector.

    1. *1: w/ Light Control Rheostat
    2. *2: w/o Light Control Rheostat

  1. Disconnect the A27 accessory meter assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    w/ Light Control Rheostat 
    Tester Connection
    Condition
    Specified Condition
    A27-3 (TH+) - A39-2
    Always
    Below 1 Ω
    A27-2 (SG) - A39-1
    A27-3 (TH+) - Body ground
    Always
    10 kΩ or higher
    A27-2 (SG) - Body ground
    w/o Light Control Rheostat 
    Tester Connection
    Condition
    Specified Condition
    A27-3 (TH+) - A26-2
    Always
    Below 1 Ω
    A27-2 (SG) - A26-1
    A27-3 (TH+) - Body ground
    Always
    10 kΩ or higher
    A27-2 (SG) - Body ground



NG
REPLACE THERMISTOR ASSEMBLY (Click here)
OK

REPLACE ACCESSORY METER ASSEMBLY (Click here)


← 12 Ambient Temperature Sensor Circuit (Aug 2012 – Jul 2013)13 Evaporator Temperature Sensor Circuit (Jun 2011 – Jul 2012) →