42 Air Inlet Damper Control Servo Motor Circuit
Diagnostic trouble codes · Vehicles built Jun 2011 – Jul 2012
Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 from Aug 2013
DESCRIPTION
The recirculation damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on the signals to move the air inlet control damper to any position, which controls the intake air settings.- HINT:
- This DTC is also output if the air inlet control damper and damper link are malfunctioning or unable to move properly. When this DTC is output, confirm that the mechanical parts of the damper and damper link are not defective or damaged.
| DTC Code |
Detection Item |
Trouble Area |
| 42 |
The air inlet control damper position does not change when the air conditioning amplifier assembly operates the recirculation damper servo sub-assembly. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- When DTC 41, 42 and 43 are output at same time, there would be malfunctioning on power source circuit (Click here).
| 1. PERFORM ACTUATOR CHECK |
Remove the glove box to visually check the recirculation damper servo sub-assembly operation (Click here).
Enter actuator check mode (Click here).
Check that the air inlet control damper position changes according to the display code.
Display Code
Air Inlet Control Damper Position
0
Fresh
1
Fresh
2
Recirculation/fresh
(50%)
3
Recirculation
4
Recirculation
5
Fresh
6
Fresh
7
Recirculation
8
Fresh
9
Fresh
- OK:
- Air inlet control damper position changes in accordance with each display code.
- HINT:
- The progression through the steps of the actuator check can be changed from automatic to manual by pressing the front DEF switch.
Result Result
Proceed to
OK (When troubleshooting according to problem symptoms table.)
A
OK (When troubleshooting according to DTC.)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. CHECK HARNESS AND CONNECTOR (RECIRCULATION DAMPER SERVO - AIR CONDITIONING AMPLIFIER) |
Disconnect the D15 recirculation damper servo sub-assembly connector.
Disconnect the A44 and A46 air conditioning amplifier assembly connectors.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for RHD Tester Connection
Condition
Specified Condition
D15-4 - A44-22 (AIR)
Always
Below 1 Ω
D15-5 - A44-23 (AIF)
D15-2 - A46-17 (PIA)
D15-3 - A46-16 (PIB)
D15-1 - A46-21 (SG-7)
D15-4 - Body ground
Always
10 kΩ or higher
D15-5 - Body ground
D15-2 - Body ground
D15-3 - Body ground
D15-1 - Body ground
for LHD Tester Connection
Condition
Specified Condition
D15-5 - A44-22 (AIR)
Always
Below 1 Ω
D15-4 - A44-23 (AIF)
D15-2 - A46-17 (PIA)
D15-3 - A46-16 (PIB)
D15-1 - A46-21 (SG-7)
D15-5 - Body ground
Always
10 kΩ or higher
D15-4 - Body ground
D15-2 - Body ground
D15-3 - Body ground
D15-1 - Body ground
|
|
||||
| OK | |
| 3. REPLACE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY |
Temporally replace the recirculation damper servo sub-assembly with a new or normally functioning one (Click here).
Check the air inlet control damper operates normally.
- OK:
- Air inlet control damper operates normally.
|
|
||||
| OK | ||
| ||