INSPECTION
Inspection · Vehicles built from Jun 2011
| INSPECT COMMON RAIL ASSEMBLY |
 |
- Measure the resistance between the terminals of the pressure sensor.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
2 - 3
|
25°C (77°F)
|
16.4 kΩ or less
|
5 - 4
|
25°C (77°F)
|
16.4 kΩ or less
|
1 - 2
|
25°C (77°F)
|
3 kΩ or less
|
6 - 5
|
25°C (77°F)
|
3 kΩ or less
|
If the result is not as specified, replace the common rail assembly.
- Measure the resistance of the Pressure discharge valve.
- Standard resistance:
- 0.85 to 1.05 Ω at 20°C (68°F)
If the result is not as specified, replace the common rail assembly.