INSPECTION
Inspection · Vehicles built from Jun 2011
| INSPECT COMMON RAIL ASSEMBLY |
Inspect the fuel pressure sensor.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
2 - 3
25°C (77°F)
16.4 kΩ or less
5 - 4
25°C (77°F)
16.4 kΩ or less
1 - 2
25°C (77°F)
3 kΩ or less
6 - 5
25°C (77°F)
3 kΩ or less
Inspect the pressure discharge valve.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
0.85 to 1.05 Ω