2014 Hilux · Service Manual HEATER & AIR CONDITIONING SYSTEM

INSPECTION

Inspection · Vehicles built from Jun 2011


INSPECT NO. 1 COOLER THERMISTOR

E184474E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ

    If the resistance is not as specified, replace the No. 1 cooler thermistor (front evaporator temperature sensor).

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (refer to the graph).

    Text in Illustration 
    *a
    Component without harness connected
    (No. 1 Cooler Thermistor (Front Evaporator Temperature Sensor))
    *b
    Sensor Part
    *c
    Resistance kΩ
    *d
    Temperature °C (°F)

← REMOVAL (from Aug 2013)INSTALLATION (Jun 2011 – Jul 2012) →