INSPECTION
Inspection · Vehicles built from Jun 2011
| INSPECT DIFFERENTIAL VACUUM ACTUATOR ASSEMBLY |
Measure the resistance between terminals 1 and 2.

Text in Illustration *1
Shift Fork
*a
2WD Side
*b
4WD Side
- Standard:
- 0.1 to 100 Ω
Measure the resistance between terminal 1 or 2 and body ground.
- Standard:
- 5 MΩ or more
Check the actuator using one of the following methods.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Measurement Condition
Specified Condition
3 - 4
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Below 1 Ω
3 - 4
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
10 kΩ or higher
4 - 5
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Below 1 Ω
4 - 5
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
10 kΩ or higher
4 - 6
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Below 1 Ω
4 - 6
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
10 kΩ or higher
Check the actuator status.
- OK:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
2WD → 4WD
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
4WD → 2WD