CAUTION / NOTICE / HINT

NOTICE:
·

When replacing the injectors (including shuffling the injectors between the cylinders), common rail or cylinder head, it is necessary to replace the injection pipes with new ones.

·

When replacing the fuel supply pump, common rail, cylinder block, cylinder head, cylinder head gasket or timing gear case, it is necessary to replace the fuel inlet pipe with a new one.

·

When replacing the common rail, do not remove the foreign object mixing prevention caps of the common rail until just before the fuel inlet pipe and injection pipe are connected to the common rail.

·

After removing the injection pipes and fuel inlet pipe, clean them with a brush and compressed air.



PROCEDURE

Hide 1.INSTALL COMMON RAIL ASSEMBLY

a.

Install the common rail with the 2 bolts.

Torque:
38 N*m (387 kgf*cm, 28 ft.*lbf)


b.

Connect the pressure discharge valve connector.


Hide 2.INSTALL VACUUM CONTROL VALVE SET (for i-ART)

a.
A271776
1.625,0.521 1.083,0.521 false 1.458,0.792 1.063,0.792 false 2.156,1.25 2.01,1.25 2.01,1.25 2.01,0.906 false 0.865,0.417 1.052,0.573 0.188,0.156 10 false *1 0.865,0.698 1.052,0.854 0.188,0.156 10 false *2 2.229,1.135 2.417,1.292 0.188,0.156 10 false *1
*1 Paint Mark (White)
*2 Paint Mark (Green)


Install the vacuum control valve set with the 2 bolts.

Torque:
20 N*m (204 kgf*cm, 15 ft.*lbf)


b.

Connect the 3 vacuum hoses and 2 vacuum switching valve connectors.

NOTICE:

When connecting the hoses, match the colors of the paint marks on the hoses to the colors of the paint marks on the swirl control valve as shown in the illustration.



Hide 9.INSTALL ELECTRIC EGR CONTROL VALVE ASSEMBLY WITH NO. 2 EGR VALVE AND EGR COOLER

Hide 10.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).