Home › Drivetrain › A750F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) › 2012.04–2012.10
RM1840EF _52 Drivetrain _009612 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0052492 AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) C

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)  P0748  Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)  


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which are controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (See page Drivetrain>A750F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)>FAIL-SAFE CHART).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1) The ECM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gear (1-trip detection logic).
Output signal duty equals 100%.
HINT:

SL1 output signal duty is less than 100% under normal conditions.


·

Open or short in shift solenoid valve SL1 circuit

·

Shift solenoid valve SL1

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Then the ECM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the circuit.

While driving and shifting between 4th and 5th gears, if the ECM detects an open or short in the shift solenoid valve SL1 circuit, the ECM determines there is a malfunction (See page Drivetrain>A750F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)>FAIL-SAFE CHART).

WIRING DIAGRAM

C219217
2.792,1.333 3.021,1.5 0.229,0.167 10 false 12 5.479,1.323 5.708,1.49 0.229,0.167 10 false 19 2.333,1.104 2.76,1.302 0.427,0.198 10 false SL1+ 2.802,2.542 3.031,2.708 0.229,0.167 10 false 4 0.813,1.427 1.042,1.594 0.229,0.167 10 false 1 0.823,2.188 1.052,2.354 0.229,0.167 10 false 2 2.365,2.323 2.792,2.521 0.427,0.198 10 false SL1- 5.75,1.219 6.177,1.417 0.427,0.198 10 false SL1+ 5.479,2.552 5.708,2.719 0.229,0.167 10 false 18 5.76,2.438 6.188,2.635 0.427,0.198 10 false SL1- 1.021,2.948 1.448,3.146 0.427,0.198 10 false C151 1.031,3.115 2.281,3.313 1.25,0.198 10 false Transmission Wire 1.042,1.792 2.688,2.021 1.646,0.229 10 false Shift Solenoid Valve SL1 5.927,3.24 6.354,3.406 0.427,0.167 10 false C130 5.938,3.385 6.365,3.583 0.427,0.198 10 false ECM

CAUTION / NOTICE / HINT

HINT:

The shift solenoid valve SL1 is turned ON/OFF normally when the shift lever is in D.

ECM gear shift command 1st 2nd 3rd 4th 5th
Shift solenoid valve SL1 OFF OFF OFF OFF ON


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1)
a.
C214326
1.708,1.323 1.531,1.75 true 1.802,1.104 2.031,1.75 true 1.344,1.781 1.708,1.948 0.365,0.167 10 false SL1+ 0.115,0.083 0.344,0.25 0.229,0.167 10 false *a 1.927,1.781 2.271,1.948 0.344,0.167 10 false SL1-
*a Component without harness connected
(Transmission Wire)


Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
12 (SL1+) - 4 (SL1-) 20°C (68°F) 5.0 to 5.6 Ω
12 (SL1+) - Body ground Always 10 kΩ or higher
4 (SL1-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL1
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C237600
0.896,0.333 1.302,0.573 0.406,0.24 0.521,2.781 0.844,2.052 true 0.896,2.052 1.302,2.802 true 1.104,2.875 1.781,3.052 0.677,0.177 10 false 18 (SL1-) 0.938,0.365 1.302,0.563 0.365,0.198 10 false C130 0.292,2.875 1.031,3.135 0.74,0.26 10 false 19 (SL1+) 0.094,0.052 0.375,0.385 0.281,0.333 10 false *a
*a Rear view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C130-19 (SL1+) - C130-18 (SL1-) 20°C (68°F) 5.0 to 5.6 Ω
C130-19 (SL1+) - Body ground Always 10 kΩ or higher
C130-18 (SL1-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SL1
a.
C197715C22
1.781,0.958 2.229,0.375 true 1.469,0.958 1.01,0.375 true 1.76,2.948 2.208,2.354 true 1.469,2.948 1.01,2.354 true 0.094,0.063 0.406,0.26 0.313,0.198 10 false *a 2.25,0.229 2.417,0.427 0.167,0.198 10 false 1 0.896,0.24 1.063,0.438 0.167,0.198 10 false 2 2.25,2.219 2.417,2.417 0.167,0.198 10 false 1 0.917,2.219 1.083,2.417 0.167,0.198 10 false 2 1.927,3.927 2.156,4.125 0.229,0.198 10 false (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 false (-)
*a Component without harness connected
(Shift Solenoid Valve SL1)


Remove shift solenoid valve SL1.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes operating noise



Result:
Proceed to
OK
NG



OK

NG