Home › Drivetrain › A750F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) › 2012.04–2012.10
RM1840EF _52 Drivetrain _009612 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0052492 AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) C

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)  P0985  Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)  P0986  Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)  


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which is controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly. In case of an open or short circuit, the ECM stops sending current to the circuit. For details, refer to the fail-safe chart (See page Drivetrain>A750F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)>FAIL-SAFE CHART).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR) The ECM detects a short in the solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic).
·

Short in shift solenoid valve SR circuit

·

Shift solenoid valve SR

·

ECM


Comes on DTC stored
P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR) The ECM detects an open in the solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic).
·

Open in shift solenoid valve SR circuit

·

Shift solenoid valve SR

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve SR is on, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve SR circuit.

When the shift solenoid valve SR is off, if its resistance is 100 kΩ or higher, the ECM determines there is an open in the shift solenoid valve SR circuit (See page Drivetrain>A750F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)>FAIL-SAFE CHART).

WIRING DIAGRAM

C220890
2.792,1.146 3.094,1.365 0.302,0.219 10 false 7 5.427,1.146 5.771,1.396 0.344,0.25 10 false 9 2.417,0.865 2.74,1.104 0.323,0.24 10 false SR 5.771,1 6.146,1.24 0.375,0.24 10 false SR 0.979,2.813 1.375,3.031 0.396,0.219 10 false C151 0.979,3.01 2.479,3.26 1.5,0.25 10 false Transmission Wire 1.042,1.75 2.896,1.948 1.854,0.198 10 false Shift Solenoid Valve SR 5.948,3.135 6.375,3.365 0.427,0.229 10 false C130 5.958,3.333 6.448,3.615 0.49,0.281 10 false ECM

CAUTION / NOTICE / HINT

HINT:

The shift solenoid valve SR turns ON/OFF normally when the shift lever is in D.

ECM gear shift command 1st 2nd 3rd 4th 5th
Shift solenoid valve SR OFF OFF OFF OFF ON


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)
a.
C214326
1.344,1.104 1.094,1.75 true 0.052,0.021 0.281,0.188 0.229,0.167 10 false *a 0.99,1.76 1.24,1.927 0.25,0.167 10 false SR
*a Component without harness connected
(Transmission Wire)


Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 (SR) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SR
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C237600
0.896,0.333 1.302,0.573 0.406,0.24 1.333,2.042 1.594,2.875 true 1.417,2.917 1.917,3.156 0.5,0.24 10 false 9 (SR) 0.938,0.365 1.302,0.563 0.365,0.198 10 false C130 0.094,0.052 0.375,0.385 0.281,0.333 10 false *a
*a Rear view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C130-9 (SR) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SR
a.
C214329
0.052,0 0.302,0.198 0.25,0.198 10 false *a 1.76,0.292 1.948,0.469 0.188,0.177 10 false (-) 2.438,0.281 2.688,0.479 0.25,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve SR)


Remove shift solenoid valve SR.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SR connector

·

Battery negative (-) → Shift solenoid valve SR body


Valve moves and makes operating noise



Result:
Proceed to
OK
NG



OK

NG