Home › Power Source / Network › 2KD-FTV BATTERY / CHARGING › GENERATOR(for BOSCH Made) › 2011.10–2012.04
RM1840EF _57 Power Source / Network _009634 2KD-FTV BATTERY / CHARGING _0052667 GENERATOR(for BOSCH Made) A

2KD-FTV BATTERY / CHARGING  GENERATOR(for BOSCH Made)  INSTALLATION  


PROCEDURE

Hide 1.INSTALL GENERATOR ASSEMBLY

A111821
1.906,1.927 2.104,2.135 0.198,0.208 10 true A 2.219,2.5 2.406,2.698 0.188,0.198 10 true B

a.

Install the generator and with the 2 bolts.

Torque:
for bolt A : 62 N*m (632 kgf*cm, 46 ft.*lbf)
for bolt B : 25 N*m (255 kgf*cm, 18 ft.*lbf)


b.

Install the generator wire with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


c.

Connect the generator connector.


Hide 4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE: