Home › Power Source / Network › 2TR-FBE BATTERY / CHARGING › GENERATOR › 2012.01–2012.04
RM1840EF _57 Power Source / Network _009637 2TR-FBE BATTERY / CHARGING _0052674 GENERATOR A

2TR-FBE BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 3.REMOVE INTAKE AIR CONNECTOR AND AIR CLEANER ASSEMBLY

Hide 5.REMOVE GENERATOR ASSEMBLY

a.

Detach the terminal cap.


b.
A099681

Remove the nut, bolt and disconnect the generator wire.


c.

Disconnect the generator connector.


d.

Remove the 2 bolts and generator.