The MIL (Malfunction Indicator Lamp) is used to indicate vehicle malfunction detections by the ECM.
By turning the ignition switch to ON, power is supplied to the MIL circuit, and the ECM provides the circuit ground which illuminates the MIL.
The MIL operation can be checked visually: When the ignition switch is first turned to ON, the MIL should be illuminated and should then turn off when the engine is started. If the MIL remains illuminated or is not illuminated, conduct the following troubleshooting procedure using the intelligent tester.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Perform troubleshooting in accordance with the chart below.
| Result | Proceed to |
|---|---|
| MIL remains on | A |
| MIL does not illuminate | B |
A
B
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Check whether any DTCs have been stored. Note them down if necessary.
Clear DTCs.
Click hereEngine / Hybrid System>1GR-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR
Check if the MIL turns off.
MIL turns off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Turn the ignition switch to ON.
Check that the MIL is not illuminated.
MIL is not illuminated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Disconnect the combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G154-30 (W) - G19-39 (CHK) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check if the MIL is illuminated when the ignition switch is turns ON.
MIL is illuminated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch to ON.
Start the engine.
| Result | Proceed to |
|---|---|
| Engine starts | A |
| Engine does not start* | B |
*: The intelligent tester cannot communicate with the ECM.
A
B
Disconnect the ECM connector.
Disconnect the combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G154-30 (W) - G19-39 (CHK) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG