The ECM constantly generates 5 V power source voltage from the battery voltage supplied to the +B (BATT) terminal to operate the microprocessor. The ECM also provides this power to the sensors through the VC output circuit.
When the VC circuit is short-circuited, the microprocessor in the ECM and sensors that are supplied power through the VC circuit are inactivated because the power is not supplied from the VC circuit. Under this condition, the system does not start up and the MIL does not illuminate even if the system malfunctions.
Under normal conditions, the MIL is illuminated for several seconds when the ignition switch is first turned to ON. The MIL goes off when the engine is started.
Check that the Malfunction Indicator Lamp (MIL) lights up when turning the ignition switch to ON.
MIL lights up
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect an intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester on.
Check the communication between the tester and ECM.
| Result | Proceed to |
|---|---|
| Communication is not possible | A |
| Communication is possible | B |
A
B
Disconnect the throttle body with motor assembly connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the accelerator pedal rod assembly connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the VVT sensor (for bank 1) connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the VVT sensor (for bank 2) connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the throttle body with motor assembly connector.
Disconnect the accelerator pedal rod assembly connector.
Disconnect the VVT sensor (for bank 1) connector.
Disconnect the VVT sensor (for bank 2) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C129-23 (VC) - Body ground | Always | 10 kΩ or higher |
| G155-26 (VCPA) - Body ground | Always | 10 kΩ or higher |
| G155-27 (VCP2) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG