The vacuum switching valve (for EGR bypass valve) is controlled by the ECM, and the opening and closing of the EGR cooler bypass valve is performed according to the vacuum applied by the vacuum pump.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P245C | EGR Cooler Bypass Control Circuit Low | Open or short in the vacuum switching valve (for EGR bypass valve) for 3 seconds (1 trip detection logic). | ·
Open or short in vacuum switching valve (for EGR bypass valve) circuit ·
Vacuum switching valve (for EGR bypass valve) ·
ECM |
Comes on | DTC stored |
| P245D | EGR Cooler Bypass Control Circuit High | Open or short in the vacuum switching valve (for EGR bypass valve) for 3 seconds (1 trip detection logic). | ·
Open or short in vacuum switching valve (for EGR bypass valve) circuit ·
Vacuum switching valve (for EGR bypass valve) ·
ECM |
Comes on | DTC stored |
| DTC Detection Drive Pattern | Ignition switch to ON for 3 seconds |
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>2KD-FTV ENGINE CONTROL>ECD SYSTEM(w/ EGR Cooler)>REGISTRATION) and initialization (See page Engine / Hybrid System>2KD-FTV ENGINE CONTROL>ECD SYSTEM(w/ EGR Cooler)>INITIALIZATION).
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
Inspect the vacuum switching valve (for EGR bypass valve).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Vacuum Switching Valve (for EGR Bypass Valve)) |
Disconnect the vacuum switching valve (for EGR bypass valve) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C100-1 - Body ground | Ignition switch to ON | 11 to 14 V |
Reconnect the vacuum switching valve (for EGR bypass valve) connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the vacuum switching valve (for EGR bypass valve) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C100-2 - C23-19 (ECBV) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C100-2 or C23-19 (ECBV) - Body ground | Always | 10 kΩ or higher |
Reconnect the vacuum switching valve (for EGR bypass valve) connector.
Reconnect the ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the ECM.
Click hereEngine / Hybrid System>2KD-FTV ENGINE CONTROL>ECM>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Repair or replace the harness or connector.
If the voltage at the vacuum switching valve (for EGR bypass valve) connector is not 11 to 14 V, repair or replace the harness and connector between the vacuum switching valve (for EGR bypass valve) and EFI relay (including the EFI No. 2 fuse).
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Clear the DTCs.
Click hereEngine / Hybrid System>2KD-FTV ENGINE CONTROL>ECD SYSTEM(w/ EGR Cooler)>DTC CHECK / CLEAR
Turn the ignition switch to ON for 3 seconds.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Confirm that the DTC is not output again.
| Proceed to |
|---|
| NEXT |
NEXT
Replace the vacuum switching valve (for EGR bypass valve).
| Proceed to |
|---|
| NEXT |
NEXT