2KD-FTV BATTERY / CHARGING  CHARGING SYSTEM  Noise Occurs from V-ribbed Belt or Generator Assembly  


PROCEDURE

1.CONFIRM PROBLEM SYMPTOM
a.

Confirm the problem symptom.


Result:
Symptom Proceed to
Noise occurs from fan and generator V belt assembly A
Noise occurs from generator assembly B



A

2.CHECK FAN AND GENERATOR V BELT FOR WEAR

B

6.CHECK FOR NOISE WHEN ROTOR IS TURNING FREELY
2.CHECK FAN AND GENERATOR V BELT FOR WEAR
a.

Check the fan and generator V belt for wear or damage.

OK:

The fan and generator V belt is not worn or damaged.



Result:
Result
OK
NG



OK

3.CHECK GENERATOR WITH CLUTCH PULLEY FOR WEAR

NG

REPLACE FAN AND GENERATOR V BELT

3.CHECK GENERATOR WITH CLUTCH PULLEY FOR WEAR
a.

Check the generator with clutch pulley grooves for wear or damage.

OK:

The generator with clutch pulley grooves are not worn or damaged.



Result:
Result
OK
NG



OK

4.CHECK FOR NOISE WHILE CLUTCH PULLEY IS OPERATING

NG

4.CHECK FOR NOISE WHILE CLUTCH PULLEY IS OPERATING
a.

Start the engine and check the generator with clutch pulley for looseness.

OK:

The generator with clutch pulley is not loose.



Result:
Result
OK
NG



OK

5.INSPECT GENERATOR WITH CLUTCH PULLEY (UNIT INSPECTION)

NG

TIGHTEN GENERATOR WITH CLUTCH PULLEY

5.INSPECT GENERATOR WITH CLUTCH PULLEY (UNIT INSPECTION)

b.

Check the installation condition of the generator pulley cap.

OK:

The generator pulley cap is not loose or missing.



c.

Check for grease leaks (for wet pulley) or particle formation due to friction (for dry pulley).

OK:

No grease leaks (for wet pulley) or large build-up of particles (for dry pulley).



d.

Check the generator with clutch pulley for misalignment (interference with the generator assembly).

OK:

The generator with clutch pulley is correctly aligned (no interference with the generator assembly).



e.
A288972

Turn the generator with clutch pulley clockwise and counterclockwise by hand and check for noise.

OK:

Noise does not occur when turned in both directions.



f.

Turn the generator with clutch pulley clockwise and counterclockwise by hand and visually check for runout.

OK:

The generator with clutch pulley does not have runout.



g.
A288971
2.365,1.438 2.604,1.083 2.604,1.083 2.813,1.083 false 2.854,0.99 3.167,1.188 0.313,0.198 10 false *a
*a Protective Tape


Using a screwdriver, hold the fan of the generator rotor assembly located inside the generator assembly in place and check that the generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.

OK:

The generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.



Result:
Result
OK
NG



OK

NG

6.CHECK FOR NOISE WHEN ROTOR IS TURNING FREELY
a.

Perform a road test and check that noise does not occur when decelerating.

OK:

Noise does not occur.



b.

Turn the engine off and check that no noise is produced by the generator with clutch pulley as the engine stops.

OK:

Noise does not occur.



Result:
Result
OK
NG



OK

7.CHECK ENGAGEMENT OF GENERATOR WITH CLUTCH PULLEY

NG

7.CHECK ENGAGEMENT OF GENERATOR WITH CLUTCH PULLEY

b.

Using a screwdriver, hold the fan in the generator rotor assembly located inside the generator assembly in place and check that the generator with clutch pulley locks when turned from counterclockwise (free turning direction) to clockwise (locking direction).

OK:

The generator with clutch pulley locks.


Result:
Result
OK
NG




OK

NG