DTC P0751 Shift Solenoid "A" Performance (Shift Solenoid Valve S1) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0751 | Gear required by the TCM does not match the actual gear when driving (2-trip detection logic). |
|
| ACTIVE TEST |
Warm up the engine.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / ECT / Active Test.
According to the display on the tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Control the Shift Position | Operate shift solenoid valves and set each shift position |
| Possible to check operation of the shift solenoid valves. [Vehicle Condition] 50 km/h (31 mph) or less |
| TCM gear shift command | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve S1 | ON | ON | OFF | OFF | OFF |
| 1.CHECK DTC OUTPUT (IN ADDITION TO DTC P0751) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / ECT / DTC.
Read the DTCs using the tester.
| Result | Proceed to |
| Only P0751 is output | A |
| P0751 and other DTCs are output | B |
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SHIFT SOLENOID VALVE SLT) |
![]() |
Remove the test plug from the transmission case and connect SST.
Connect the intelligent tester to the DLC3.
Start the engine and warm it up.
Measure the line pressure with SST.
Turn the intelligent tester on.
Enter the following menus: Powertrain / ECT / Active Test.
According to the display on the tester, perform the Active Test.
Measure the line pressure.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Activate the Solenoid (SLT)* | Operate shift solenoid valve SLT and raise line pressure | ON or OFF
| [Vehicle Condition]
|
|
| ||||
| OK | |
| 3.INSPECT SHIFT SOLENOID VALVE S1 |
![]() |
Remove shift solenoid valve S1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
| *a | Component without harness connected (Shift Solenoid Valve S1) |
|
| ||||
| OK | |
| 4.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly (Click here).
|
| ||||