Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Driver Side Seat Belt Warning Light does not Operate

for Preparation Click here


WIRING DIAGRAM


E169489E42


E169489E43


INSPECTION PROCEDURE

1.CHECK SEAT TYPE
  1. Check seat type.
    Result 
    Result
    Proceed to
    w/ Power Seat Control System
    A
    w/o Power Seat Control System
    B



B
Go to step 4
A


2.INSPECT FRONT SEAT INNER BELT ASSEMBLY LH (BUCKLE SWITCH)
E174267E02
  1. Disconnect the F22 belt connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 4
    Seat belt is unfastened
    Below 1 Ω
    1 - 4
    Seat belt is fastened
    1 MΩ or higher



NG
REPLACE FRONT SEAT INNER BELT ASSEMBLY LH (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (FRONT SEAT INNER BELT LH - COMBINATION METER)


    E171441E08
  1. Disconnect the F22 belt connector.



    E169370E07
  1. Disconnect the C26 meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F22-1 - C26-11
    Always
    Below 1 Ω
    F22-4 - Body ground
    Always
    Below 1 Ω
    F22-1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)  

4.INSPECT FRONT SEAT INNER BELT ASSEMBLY LH (BUCKLE SWITCH)
E174266E02
  1. Disconnect the F11 belt connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Seat belt is unfastened
    Below 1 Ω
    1 - 2
    Seat belt is fastened
    1 MΩ or higher



NG
REPLACE FRONT SEAT INNER BELT ASSEMBLY LH (Click here)
OK


5.CHECK HARNESS AND CONNECTOR (FRONT SEAT INNER BELT LH - COMBINATION METER)


    E169495E17
  1. Disconnect the F11 belt connector.



    E169370E07
  1. Disconnect the C26 meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F11-1 - C26-11
    Always
    Below 1 Ω
    F11-2 - Body ground
    Always
    Below 1 Ω
    F11-1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)