AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Blower Motor Circuit |


| 1.INSPECT BLOWER WITH FAN MOTOR SUB-ASSEMBLY |
![]() |
Remove the blower with fan motor sub-assembly (Click here).
Apply battery voltage to the blower with fan motor sub-assembly and check the operation of the blower motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 | The blower motor operates smoothly |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - AIR CONDITIONING AMPLIFIER AND BODY GROUND) |
Disconnect the B6 blower motor control connector.
Disconnect the A44 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B6-3 (SI) - A44-2 (BLW) | Always | Below 1 Ω |
| B6-4 (GND) - Body ground | ||
| B6-3 (SI) - Body ground | Always | 10 kΩ or higher |
| B6-2 (+B) - Body ground | ||
| B6-1 (VM) - Body ground |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL AND BLOWER WITH FAN MOTOR - BATTERY) |
Disconnect the B6 blower motor control connector.
Disconnect the B13 blower with fan motor sub-assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B6-2 (+B) - Body ground |
| 11 to 14 V |
| Below 1 V | |
| B13-2 - Body ground |
| 11 to 14 V |
| Below 1 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B13-1 - Body ground | Always | 10 kΩ or higher |
| B13-2 - Body ground | ||
| B6-1 (VM) - B13-1 | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY |
![]() |
Remove the air conditioning amplifier assembly with its connectors still connected (Click here).
Using an oscilloscope, check the waveform of the amplifier.
| Item | Content |
| Tester Connection | A44-2 (BLW) - Body ground |
| Tool Setting | 1 V/DIV., 50 μsec./DIV. |
| Condition | Ignition switch ON, Blower switch on (LO level) |
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
|
| ||||
| OK | ||
| ||