The FUEL PMP/AIR PMP HTR relay switches the fuel pump speed according to the engine conditions. The fuel pump operates when the ECM receives the STA signal and NE signal. The FUEL PMP/AIR PMP HTR relay is turned on while the engine is idling or operating at low load. This causes current to flow through the fuel pump resistor to the fuel pump. The fuel pump then operates at low speed. The FUEL PMP/AIR PMP HTR relay is turned off while the engine is cranking or operating at high load. The fuel pump then operates at normal speed.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0230 | Fuel Pump Primary Circuit | Open or short in FUEL PMP/AIR PMP HTR relay circuit
(1 trip detection logic) |
·
Open or short in FUEL PMP/AIR PMP HTR relay circuit ·
FUEL PMP/AIR PMP HTR relay ·
ECM |
- | DTC stored |
This DTC is designed to detect a malfunction in the FUEL PMP/AIR PMP HTR relay circuit. When the system is normal, battery voltage is applied to the FPR terminal of the ECM while the FUEL PMP/AIR PMP HTR relay is off. If battery voltage is not applied to the FPR terminal while the FUEL PMP/AIR PMP HTR relay is off, the ECM interprets this as a malfunction. The ECM then illuminates the MIL and stores a DTC.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Inspect the FUEL PMP/AIR PMP HTR relay.
Click hereEngine / Hybrid System>1GR-FE ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Engine Room Relay Block Assembly |
| *2 | FUEL PMP/AIR PMP HTR |
Remove the FUEL PMP/AIR PMP HTR relay from the Engine Room Relay Block Assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| FUEL PMP/AIR PMP HTR relay terminal 2 - Body ground | Cranking | 11 to 14 V |
| FUEL PMP/AIR PMP HTR relay terminal 2 - Body ground | Engine switch on (IG) | 0 to 3 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the FUEL PMP/AIR PMP HTR relay from the Engine Room Relay Block Assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| FUEL PMP/AIR PMP HTR relay terminal 1 - G158-4 (FPR) | Always | Below 1 Ω |
| FUEL PMP/AIR PMP HTR relay terminal 1 or G158-4 (FPR) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG