Home › Engine / Hybrid System › 1KD-FTV ENGINE CONTROL › ECD SYSTEM
RM33K0E _51 Engine / Hybrid System _043566 1KD-FTV ENGINE CONTROL _0222113 ECD SYSTEM C

1KD-FTV ENGINE CONTROL  ECD SYSTEM  P0100  Mass Air Flow Circuit  P0102  Mass Air Flow Circuit Low  P0103  Mass Air Flow Circuit High  


DESCRIPTION

The mass air flow meter uses a platinum hot wire. The mass air flow meter consists of a platinum hot wire, a temperature sensor and a control circuit installed in a plastic housing. The mass air flow meter works on the principle that the hot wire and temperature sensor located in the intake air by-pass of the housing detect any changes in the intake air temperature.

The hot wire is maintained at the predetermined temperature by controlling the current flow through the hot wire. This current flow is then related as the output voltage of the mass air flow meter.

The circuit is constructed so that the platinum hot wire and temperature sensor provide a bridge circuit, with the power transistor controlled so that the potential of A and B remains equal to maintain the predetermined temperature.

A122492E11
1.417,0.5 1.917,1.5 true 2.635,1.063 2.292,1.49 false 4.698,1.26 4.073,2.156 true 5.031,1.552 5.521,2.198 true 0.104,0.375 1.396,0.604 1.292,0.229 10 false Temperature Sensor 2.167,0.146 2.448,0.365 0.281,0.219 10 false B+ 2.208,0.542 3.333,0.802 1.125,0.26 10 false Power Transistor 2.677,0.958 4.406,1.188 1.729,0.229 10 false Platinum Hot Wire (Heater) 1.667,1.479 1.833,1.688 0.167,0.208 10 false A 2.469,1.479 2.656,1.677 0.188,0.198 10 false B 2.896,1.583 3.927,1.813 1.031,0.229 10 false Output Voltage 5.167,2.188 6.979,2.438 1.813,0.25 10 false Platinum Hot Wire (Heater) 3.344,2.188 4.677,2.396 1.333,0.208 10 false Temperature Sensor

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0100 Mass Air Flow Circuit Malfunction Mass air flow meter voltage is 0.2 V or less, or 4.9 V or more with the engine speed at 2000 rpm or less for 3 seconds (1 trip detection logic).
·

Open or short in mass air flow meter circuit

·

Mass air flow meter

·

ECM


Comes on DTC stored
P0102 Mass Air Flow Circuit Low Mass air flow meter voltage is 0.2 V or less with the engine speed at 2000 rpm or less for 3 seconds (1 trip detection logic).
·

Open or short in mass air flow meter circuit

·

Mass air flow meter

·

ECM


Comes on DTC stored
P0103 Mass Air Flow Circuit High Mass air flow meter voltage is 4.9 V or more with the engine speed at 2000 rpm or less for 3 seconds (1 trip detection logic).
·

Open or short in Mass air flow meter circuit

·

Mass air flow meter

·

ECM


Comes on DTC stored

Related Data List
DTC No. Data List
P0100 MAF
P0102
P0103

HINT:
·

If DTC P0102 is stored, the following symptoms may appear:

·

Combustion noise worsens


·

If DTC P0103 is stored, the following symptoms may appear:

·

Misfire

·

White smoke

·

Black smoke


·

After confirming DTC P0100, P0102 or P0103, check the mass air flow ratio in the following menus: Powertrain / Engine / Data List / MAF using the GTS.

Reference
Air Flow Value (gm/sec) Malfunction
Approximately 0.0
·

Open in mass air flow meter power source circuit

·

Open or short in VG circuit


167.5 or more Open in EVG circuit



CONFIRMATION DRIVING PATTERN

P0100, P0102, P0103
DTC Detection Drive Pattern 3 seconds after engine is started

WIRING DIAGRAM

A377666E01
1.854,1.563 2.927,1.948 1.073,0.385 10 false Instrument Panel Junction Block 1.656,1.281 2.74,1.469 1.083,0.188 10 false EFI-MAIN NO. 1 1.354,1.354 1.542,1.542 0.188,0.188 10 false 2J 1.313,1.167 1.5,1.354 0.188,0.188 10 false 5 0.615,0.583 0.802,0.771 0.188,0.188 10 false 2B 0.635,0.385 0.823,0.573 0.188,0.188 10 false 1 0.448,1.844 1,2.031 0.552,0.188 10 false J/B-B 0.677,3.083 1.229,3.271 0.552,0.188 10 false Battery 0.49,2.427 1.521,2.625 1.031,0.198 10 false FL MAIN 3.0W 0.948,0.708 1.594,1.063 0.646,0.354 10 false EFI-MAIN NO. 1 2.302,0.708 2.948,1.063 0.646,0.354 10 false EFI NO. 1 3.021,0.573 3.208,0.76 0.188,0.188 10 false 2K 3.021,0.917 3.208,1.104 0.188,0.188 10 false 2P 3.875,1.792 4.198,1.979 0.323,0.188 10 false A68 3.875,1.969 5.26,2.156 1.385,0.188 10 false Mass Air Flow Meter 3.073,0.417 3.26,0.604 0.188,0.188 10 false 1 3.719,0.49 3.906,0.677 0.188,0.188 10 false 1 3.063,0.76 3.25,0.948 0.188,0.188 10 false 9 5.125,0.802 5.313,0.99 0.188,0.188 10 false 3 5.125,1.292 5.313,1.479 0.188,0.188 10 false 2 5.417,0.896 5.74,1.083 0.323,0.188 10 false C74 5.427,1.396 5.75,1.583 0.323,0.188 10 false C74 5.344,2.813 5.74,3.01 0.396,0.198 10 false G130 5.458,0.698 5.688,0.885 0.229,0.188 10 false 24 5.458,1.219 5.688,1.406 0.229,0.188 10 false 32 5.448,2.635 5.677,2.823 0.229,0.188 10 false 8 5.76,2.698 6.219,2.875 0.458,0.177 10 false MREL 5.76,1.302 6.219,1.479 0.458,0.177 10 false EVG 5.76,0.802 6.219,0.979 0.458,0.177 10 false VG 6.135,3.271 6.594,3.448 0.458,0.177 10 false ECM

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses of circuits related to this system before performing the following inspection procedure.

·

After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM>REGISTRATION) and initialization (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM>INITIALIZATION).



HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.INSPECT MASS AIR FLOW METER (POWER SOURCE CIRCUIT)
a.
A107942C31
0.5,1.063 0.917,1.313 0.417,0.25 1.219,1.823 1.396,1.5 true 0.115,0.135 0.281,0.302 0.167,0.167 10 false *a 0.594,1.104 0.885,1.26 0.292,0.156 10 false A68 1.052,1.813 1.365,1.979 0.313,0.167 10 false +B
*a Front view of wire harness connector
(to Mass Air Flow Meter)


Disconnect the mass air flow meter connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A68-1 (+B) - Body ground Ignition switch ON 11 to 14 V



c.

Reconnect the mass air flow meter connector.


Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)

NG

8.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY)
2.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
a.

Disconnect the mass air flow meter connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A68-3 (VG) - C74-24 (VG) Always Below 1 Ω
A68-2 (E2G) - C74-32 (EVG) Always Below 1 Ω
A68-3 (VG) or C74-24 (VG) - Body ground Always 10 kΩ or higher



d.

Reconnect the mass air flow meter connector.


e.

Reconnect the ECM connector.


Result:
Proceed to
OK
NG



OK

3.REPLACE MASS AIR FLOW METER

NG

7.REPAIR OR REPLACE HARNESS OR CONNECTOR
3.REPLACE MASS AIR FLOW METER

Result:
Proceed to
NEXT



NEXT

4.CHECK WHETHER DTC OUTPUT RECURS (DTC P0100, P0102 AND/OR P0103)
4.CHECK WHETHER DTC OUTPUT RECURS (DTC P0100, P0102 AND/OR P0103)
a.

Connect the GTS to the DLC3.


b.

Clear the DTCs.

Powertrain > Engine > Clear DTCs
50002 234

c.

Start the engine and wait for 3 seconds or more.


d.

Enter the following menus: Powertrain / Engine / Trouble Codes.

Powertrain > Engine > Trouble Codes
50001 234

e.

Read the DTCs.

Result:
Result Proceed to
P0100, P0102 and/or P0103 is output A
No DTC is output B




A

5.REPLACE ECM

B

END

5.REPLACE ECM

Result:
Proceed to
NEXT



NEXT

6.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
6.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
a.

Connect the GTS to the DLC3.


b.

Clear the DTCs.

Powertrain > Engine > Clear DTCs
50002 234

c.

Start the engine and wait for 3 seconds or more.


d.

Enter the following menus: Powertrain / Engine / Trouble Codes.

Powertrain > Engine > Trouble Codes
50001 234

e.

Confirm that the DTC is not output again.


Result:
Proceed to
NEXT



NEXT

END

7.REPAIR OR REPLACE HARNESS OR CONNECTOR
a.

Repair or replace the harness or connector.


Result:
Proceed to
NEXT



NEXT

6.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
8.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY)
a.

Disconnect the mass air flow meter connector.


b.

Disconnect the instrument panel junction block connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A68-1 (+B) - 2K-1 Always Below 1 Ω
A68-1 (+B) or 2K-1 - Body ground Always 10 kΩ or higher



d.

Reconnect the mass air flow meter connector.


e.

Reinstall the instrument panel junction block connector.


Result:
Proceed to
OK
NG



OK

9.CHECK ECM POWER SOURCE CIRCUIT

NG

7.REPAIR OR REPLACE HARNESS OR CONNECTOR
9.CHECK ECM POWER SOURCE CIRCUIT

Result:
Proceed to
NEXT



NEXT

6.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED